Installation Manual for SX-4000 Standalone
Integrated Media Block™
with Enterprise Storage/Enterprise Storage Plus
13. COMPONENT ENGINEERING TA-10 SETUP
13.
COMPONENT ENGINEERING TA-10 SETUP
The Component Engineering TA-10 can be used for theater automation with the SX-4000. It
requires that the TA-10 be wired in a particular configuration. A wiring diagram can be seen in
Figure 60.
The TA-10 is connected to the SX-4000
using the server’s GPIO input/output port.
Configure
event labels with the GPIO device to trigger the TA-10.
Figure 57 Component Engineering TA-10 wiring diagram.
14.
TESTING PROCEDURES AFTER
INSTALLATION
After the installation has been completed, it is necessary to test the following to ensure that the
SX-4000 has been properly installed:
1. Test the video playback capabilities of the server using the following file formats: MPEG2,
JPEG2000, Scope, Flat, 3D.
2. Test the audio playback capabilities of the server and verify that all the channels are
working. Also check for any static noises.
3.
Test the server’s ability to activate automation cues using test cues for lights, curtains,
sound and fire alarm.
4. Test the remote access capabilities of the server, including: Theatre Management
System (TMS) access, network connectivity and VNC.