Wiring Diagrams

Fire Alarm Override

 9

Wiring Diagrams

Wiring for StrikeLock only using 12 - 24VAC supply

Note: All OV shown in the
diagram are connected to
OV of the Door Control.

0V

12V
0V
NO
COM
NC

12 - 24 VAC

12 - 24 VAC

   16V
Varistor

12V
0V
NO
COM
NC

IP3
IP2
IP1

OP1
OP2

12V Linear
Power supply

A

B

T

AMP

T

AMP

Alarm Panel connections

Wiring for StrikeLock only using 12 - 24VAC supply

Note: All OV shown in the
diagram are connected to
OV of the Door Control.

0V

12V
0V
NO
COM
NC

12 - 24 VAC

12 - 24 VAC

   16V
Varistor

12V
0V
NO
COM
NC

IP3
IP2
IP1

OP1
OP2

12V Linear
Power supply

A

B

T

AMP

T

AMP

Door

Exit Button

Door

Contact

0V

0V

Door

Exit Button

0V

Door
Contact

0V

Arm Alarm Input

Arm Output (N/O)

Alarm Panel

Alarm Panel Notes:

Common OV from the
Intruder Alarm Panel

and the OV from the

Door Control to avoid
any ground loop issues.

Only the Manager User
can activate/deactivate
the Alarm Panel. When
the Alarm Panel is
activated all other users
are locked out.

Select the Panel Alarm option
from the drop-down list
for IP3 on the PC application
for this Door Control.

Fire Alarm

Panel

FireAlarm Panel Notes:

Common OV from the
Fire Alarm Panel

and the OV from the

Door Control to avoid
any ground loop issues.

When the fire alarm

is activated (0V removed

from IP3) the door will
be opened.

Select the Fire Alarm Override option
from the drop-down list
for IP3 on the PC application
for this Door Control.

0V

12V

   16V
Varistor

Door

MagLock

Break Glass

Unit

12V

   16V
Varistor

Door

MagLock

Break Glass

Unit

0V

0V

Summary of Contents for Wi-Pin & Prox

Page 1: ...or Controls Wi Pin Prox Wi Pin Wi Prox Other products from GSD Installation User Manual V2 06 Global Security Devices Ltd No 3 Broomhill Business Complex Tallaght Dublin 24 Ireland Phone 353 1 524 269...

Page 2: ...of the Door Control 2 Replace the Defaulting Link Jumper on the Door Control 3 Remove the Defaulting Link Jumper immediately after the Green LED turns ON It will take 5 seconds to switch ON 4 This wi...

Page 3: ...ity screws provided Both Security Caps are then clipped onto the Door Control To attach Security Caps Simply align the tabs into holes and push on until click is heard Surface Mounting Security Caps 5...

Page 4: ...12 24VAC supply Note All OV shown in the diagram are connected to OV of the Door Control 0V 12V 0V NO COM NC 12 24 VAC 12 24 VAC 16V Varistor 12V 0V NO COM NC IP3 IP2 IP1 OP1 OP2 12V Linear Power supp...

Page 5: ...ontact 0V Arm Alarm Input Arm Output N O Alarm Panel Alarm Panel Notes Common OV from the Intruder Alarm Panel and the OV from the Door Control to avoid any ground loop issues Only the Manager User ca...

Page 6: ...0V NO COM NC IP3 IP2 IP1 OP1 OP2 12V Linear Power supply A B TAMP TAMP Interlock OP to Interlock IP on 2nd Door Interlock IP from Interlock OP on 2nd Door Door Contact 0V 0V Door Exit Button Select t...

Page 7: ...efault each Door Control 3 On PC application Doors Tab Click on Add New Door to add a new door to the system 4 Enrolling On a New System Install On PC application Controller Tab Wireless Network Click...

Page 8: ...ed an address all unassigned Door Controls will start to beep the next available address 3 When all doors are assigned Click Secure Network Assigning a Door Address on a Wired 485 Network Step Descrip...

Reviews: