Page 4 - 23
Installation
Digital Feeder Operation and Maintenance Manual
© GBC Pro - Tech February 2000
4.10 Control panel check
The control panel should be checked to ensure
all controls function properly. Confirm the control panel
display reflects the input accordingly. The specific function
of each command is explained in Section 5 Operations.
Although RUN and VACUUM commands have
been pressed in previous steps, press them again in this
procedure to confirm the display changes.
RUN
a) Press RUN
ON
. An audible beep sounds
and the
ON
is illuminated.
R U N
O N
OFF
- Display shows
DIGITAL FEEDER
G B C
RUN ON VAC. OFF
J O B 1 TABLE STOP
SHEET 7 28/32"
GAP 00/32"
b) Press RUN
OFF
. An audible beep sounds
and the
ON
light extinguishes.
R U N
O N
OFF
- Display shows
DIGITAL FEEDER
G B C
RUN OFF VAC. OFF
J O B 1 TABLE STOP
SHEET 7 28/32"
GAP 00/32"
VACUUM
a) Press VACUUM
ON
. An audible beep
sounds and the
ON
is illuminated.
V A C U U M
O N
OFF