Two Operational Modes - Analyze and Setup 

1.  Analyze Mode. 

The instrument automatically goes into Analyze Mode when power is applied and is ready 

to measure moisture in a bale. The image below left is the Analyze screen and below right is the Setup Menu. 

The ISObus terminal in the tractor will display the moisture via the analyze screen as soon as a measurement 
has been made. From this screen, touch the setup icon (cog 

 top right) to enter the Setup Menu. 

 

 

 

 

 

 

 

 

 

The Analyze screen displays the three moisture readings, now (update every 5 seconds), average (per bale 
or 2 minutes) and max (per bale or 2 minutes).

 

 

From the Gazeeka Analyze screen you can change the crop type equation, set the moisture at which the 

 

spray cans will mark (

S

) the bale and do a manual marking of the bale at any time (

“Spray”

). 

 

Although  the  universal  equation  (as  selected  above)  is  suitable  for  all  hay  types,  the  accuracy  may  be 

 

improved a little by selecting the appropriate fodder / forage type. 

 

Typical  status  words  include:  START  UP,  READING,  WAITING,  STOPPED,  BALE  END  and  NO  BALE. 

 

These will appear as green status’ in the status line (as per the “No Bale” status featured above). This is also 

 

where red status alerts (errors) and yellow status updates will appear 

 if detected by the Gazeeka system. 

2.  Setup Mode

.  From the Gazeeka Analyze screen press the setup icon to get to the Setup screen. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

See the list on the reverse side for details about each parameter. The test button is only used for diagnostic 

 

purposes. Go back to the Analyze mode when you have completed any changes in the Setup mode. 

Note

: If marker cans have not been used for some time, they may occasionally require to be shaken. 

Air Standardization (Air Cal.) in Setup Mode 

An "air standardization" (or Air Cal.) must be carried out 

with the tractor running

 at: (1) the time of installation;               

(2) if there are any physical changes to the installation (new baler, microwave cable or electronics) or (3) at the start 
if each season. This operation is carried out as follows, 

with the tractor running: 

  Make sure the instrument has been on for at least 2 minutes. 

  Make sure the air path between the antennae is clear (i.e., no bale or anything else within at least 2 feet). 

 

Press the “Air” button

 (It w

ill ask you to press “Air” again to remind you to make 

sure the path is clear). 

  If no error message is displayed, the air path standardization has been completed OK. 

  Go back to the Gazeeka Analyze screen. The instrument is now ready to start measuring bales again. 

Calibration Check Module 

  This instrument contains a Calibration Check Module. The calibration of the microwave system can 

be checked using this module.  

Please refer to section 6.3 of the manual for operation.

QUICK REFERENCE CARD 

V22p00 

Close settings and return to Analyze Mode 

Air is used to do an air cal. on a clear no bale path (

with tractor running

Last cursor is used to navigate setup screens 

Test is used by technicians to get microwave data or to conduct a CCM   
test 

 

see section 6.3 of the Owner’s Manual.

 

Next cursor is used to navigate setup screens 