Place the heatsink onto the processor, then push down the heatsink retaining levers and
lock them under the retaining hooks on the heatsink socket.
11
Follow the instructions in
“Closing the server case” on page 27
.
Replacing a power supply module
Your server uses as many as three 700 W hot-swappable power supply modules. If your server
has more than one power supply module installed, the modules act as redundant, hot-swappable
power supplies. If one of the power supply modules fails, the other power supply module(s)
support the server while you replace the failed module. You do not need to turn off the server
or disconnect peripheral devices to replace a failed redundant power supply module.
If your server is only equipped with a single power supply module, the server must be turned
off and the AC power cord removed before replacing the module.
To replace a power supply module:
1
If your server is equipped with more than one power supply module, determine which
power supply module has failed (the LED on the power supply will be orange).
2
If your server has only one power supply module installed, make sure that you turn off
the server, then unplug the power cord before continuing.
- OR -
If your server has two or more power supply modules installed, you do not need to turn
off the power to the server before continuing.
Caution
The heatsink has Thermal Interface Material (TIM) located on the bottom of
it. Use caution when you unpack the heatsink so you do not damage the TIM. If
you are reusing the original heatsink, make sure that the TIM on the bottom of
the heatsink is not damaged. If the TIM is damaged, you should remove the old
TIM, then apply new TIM to the bottom of the heatsink.
Caution
The power supplies in this server contain no user-serviceable parts. Only a qualified
computer technician should service the power supplies.
Your server comes with 3-wire AC power cords fitted with the correct plug style for your
region. If this plug does not match the connector on your surge protector, UPS, or wall
outlet, do not attempt to modify the plug in any way. Use a surge protector, UPS, or wall
outlet that is appropriate for the supplied AC power cords.
Summary of Contents for E-9722R
Page 1: ... E 9722R Server USERGUIDE ...
Page 2: ......
Page 6: ...Contents iv ...
Page 16: ...CHAPTER 1 Checking Out Your Gateway Server 10 ...
Page 28: ...CHAPTER 3 Maintaining Your Server 22 ...
Page 58: ...CHAPTER 4 Installing Components 52 ...
Page 66: ...CHAPTER 5 Using the BIOS Setup Utility 60 ...
Page 84: ...CHAPTER 6 Troubleshooting 78 ...
Page 92: ...APPENDIX A Server Specifications 86 ...
Page 93: ...APPENDIXB 87 BIOS Settings ...
Page 101: ...APPENDIXC 95 Legal Information ...
Page 106: ...APPENDIX C Legal Information 100 ...
Page 110: ...Contents 104 ...
Page 111: ......
Page 112: ...A MAN E 9722R USR R0 02 07 ...