Chapter 4: Installing Components
Replacing the hot-swap backplane
Your server may have a single hot-swap cage (standard) that can hold six SATA drives, or
two hot-swap cages (optional) that can hold six and four SCSI drives, respectively. Each
hot-swap cage is connected to a backplane. The pictures in this procedure show replacing
the upper backplane. The other backplane (optional) can be installed or replaced in the
same manner.
To replace the hot-swap backplane:
1
Follow the instructions in
“Preventing static electricity discharge” on page 41
2
Follow the instructions in
“Opening the server case” on page 42
.
3
Follow the instructions in
“Removing the bezel assembly” on page 44
.
4
Remove the fan nearest the backplane (if installed). For instructions, see
.
5
Remove each of the drives from the hot-swap cage, and note the location of each
drive. For instructions, see
“Installing a hot-swap hard drive” on page 59
. Go to
.
- OR -
If you are installing a new, four-drive SCSI hot-swap cage, remove the screw securing
the drive bay door to the chassis, then remove the door. Go to
6
Push up on the drive release latch for the hot-swap cage you are removing.
8510725.book Page 86 Tuesday, May 17, 2005 5:45 PM