Power supply fans
Power supply fans are monitored and controlled by the power subsystem. A fan failure
(predicted or current) will show up in the IMM System Event Log (
SEL
) as a “Power Unit
0x01h” failure event and a GSM event will show up as “Power Unit Failure Detected.”
Power supply fans are not monitored by the mini-BMC, therefore no SEL or GSM events
will be reported with the mini-BMC configuration.
When a predicted or current fan failure is reported, the server must be opened to determine
which fan is having problems. LEDs on the power distribution board will indicate which
fan requires attention. The appropriate LED will blink to indicate a slow fan and light to
show a failed fan. The PS Fan 1 is on the left side of the module.
To replace a power supply fan:
1
Follow the instructions in
“Preventing static electricity discharge” on page 41
. Make
sure that you turn off the server, then unplug the power cord(s) and all other cables
connected to the server.
2
Follow the instructions in
“Opening the server case” on page 42
.
PS Fan 1 LED
PS Fan 2
LED
8510522.book Page 80 Wednesday, March 16, 2005 11:19 AM
Summary of Contents for 9415
Page 1: ...User Guide Gateway 9415 Server ...
Page 5: ...iv www gateway com 8510522 book Page iv Wednesday March 16 2005 11 19 AM ...
Page 121: ...116 www gateway com 8510522 book Page 116 Wednesday March 16 2005 11 19 AM ...
Page 145: ...140 www gateway com 8510522 book Page 140 Wednesday March 16 2005 11 19 AM ...
Page 171: ...166 www gateway com 8510522 book Page 166 Wednesday March 16 2005 11 19 AM ...
Page 187: ...182 www gateway com 8510522 book Page 182 Wednesday March 16 2005 11 19 AM ...
Page 188: ...A MAN 9415 USR GDE R0 03 05 ...