Reference Data
Environmental specifications
The following specifications identify maximum environmental conditions. At
no time should the server run under conditions which violate these
specifications.
PCI Expansion Slots
Six full length, hot-pluggable PCI slots (four 64-bit, 33MHz and two 64-bit,
66MHz), and two half-length PCI slots (32-bit, 33MHz).
Power Supply
One to three, 375 watt power supplies.
Certification
FCC Class A, UL, CUL, CE Mark, VCCI, CB Scheme.
Variable
Requirements
Temperature
Maximum rate of change = 10° C per hour
Nonoperating
–40° to 70 °C (–38° to 158 °F)
Operating
10° to 35 °C (50° to 95 °F); derated 0.5 °C for every
1000 ft. (305 m), with a maximum rate of change of
10°C/Hour
Altitude
10,000 ft. max
Humidity
Nonoperating
95% relative (noncondensing) @ 30° C (86° F)
Shock
Operating
2.0 g, 11 msec, 1/2 sine
Packaged
Operational after 30-inch free fall (cosmetic damage
might occur)
05895.book Page 130 Thursday, May 11, 2000 1:11 PM
Summary of Contents for 8400
Page 1: ...8400 Server System Manual A MAN US 8400 SYS GDE R0 5 00 ...
Page 5: ...iv 05895 book Page iv Thursday May 11 2000 1 11 PM ...
Page 9: ...viii 05895 book Page viii Thursday May 11 2000 1 11 PM ...
Page 87: ...78 Using the BIOS Setup Utility 05895 book Page 78 Thursday May 11 2000 1 11 PM ...
Page 121: ...112 Troubleshooting 05895 book Page 112 Thursday May 11 2000 1 11 PM ...
Page 137: ...128 Safety and Regulatory Information 05895 book Page 128 Thursday May 11 2000 1 11 PM ...
Page 146: ...8400 Server System Manual A MAN US 8400 SYS GDE R0 5 00 ...