72
Using the BIOS Setup Utility
Intrusion Detection Enable jumper
The Intrusion Detection Enable jumper on the system board (pins 5 through 7
on jumper J3J1) lets you enable intrusion detection. (See the figure on page 6
for the location of the jumper.)
The following table shows the settings required to enable intrusion detection.
Make sure you turn off the server and unplug the power cord before moving
the jumper.
BMC Firmware Update jumper
The BMC Firmware Update jumper on the system board (pins 9 through 11
on jumper J3J1) lets you update the BMC firmware during system boot. (See
the figure on page 6 for the location of the jumper.)
Mode
Jumper
Setting
Action When Set
Enable
Pins 5-6
Intrusion detection is enabled
(default)
Disable
Pins 6-7
Intrusion detection is disabled
Caution
Moving the jumper while the power is on can damage the
server. Always turn off the server and unplug the power
cord before moving the jumper.