116
System Specifications
Environmental specifications
The following specifications identify maximum environmental conditions. At
no time should the server run under conditions which violate these
specifications.
System I/O addresses
The following table shows the location in I/O space of all directly
I/O-accessible registers.
Temperature, operating
5° to 35° Celsius or
44° to 95° Fahrenheit.
Humidity, operating
20% to 80%
Altitude
-200 feet to 10,000 feet
Voltage, AC input
90 to 135 VAC, 180 to 255 VAC
Frequency
47 to 63 Hz
Certification
FCC Class A, UL, CUL, CAN/CSA STD C22.2 No. 950,
CE Mark, VCCI Class A, CB scheme
Address
Resource
0000h - 000Fh
DMA Controller 1
0010h - 001Fh
DMA Controller 1
0020h - 0021h
Interrupt Controller 1
0022h - 0023h
0024h - 0025h
Interrupt Controller 1
0026h - 0027h
0028h - 0029h
Interrupt Controller 1
002Ah - 002Bh
002Ch - 002Dh
Interrupt Controller 1
002Eh - 002Fh
Super I/O Index and Data Ports
0030h - 0031h
Interrupt Controller 1
0032h - 0033h
0034h - 0035h
Interrupt Controller 1
0036h - 0037h
0038h - 0039h
Interrupt Controller 1
003Ah - 003Bh
003Ch - 003Dh
Interrupt Controller 1
8506162.book Page 116 Wednesday, May 10, 2000 10:21 AM
Summary of Contents for 7250R
Page 1: ...A MAN US 7250R SYS RACK GDE R0 4 00 7250R Server System Manual ...
Page 5: ...iv 8506162 book Page iv Wednesday May 10 2000 10 21 AM ...
Page 23: ...16 System Setup 8506162 book Page 16 Wednesday May 10 2000 10 21 AM ...
Page 29: ...22 Case Access 8506162 book Page 22 Wednesday May 10 2000 10 21 AM ...
Page 81: ...74 Using the BIOS Setup Utility 8506162 book Page 74 Wednesday May 10 2000 10 21 AM ...
Page 121: ...114 Safety Regulatory and Notices 8506162 book Page 114 Wednesday May 10 2000 10 21 AM ...
Page 135: ...A MAN US 7250R SYS RACK GDE R0 4 00 7250R Server System Manual ...