2 – Functional Description & Setup
Intraplex VF-40 Voice Module
Version 1.11
GatesAir
2-11
Intraplex Products
Table 2-6. Remote Configuration Settings (P Codes)
P
Code
Settings
7 6 5 4 3 2 1 0
Value*
Description
P1
B 0 0
0
0
↑
0
↑
0
↑
0
↑
0
↑
00001
to
11111
From left to right, these five bits represent the
binary value of the starting time slot (Tables 2-4
and 2-5).
TIME SLOT SELECT
B
0
↑
0
↑
0
↑
0
0
0
0
0
Not used
P3
B
0
0
0
0
0
0
0
0
↑
0
1
Set to operate through the DI-B port in a drop and
insert multiplexer.
Set to operate in a terminal multiplexer or through
the DI-A port in a drop and insert multiplexer.
TERMINAL
B
0
0
0
0
0
0
0
↑
0
0
1
Normal - local loopback off
Local loopback active
LOCAL LOOPBACK
B
0
0
0
0
0
0
↑
0
0
0
1
Normal - Channel 1 remote loopback off
Channel 1 remote loopback active
CH. 1 REMOTE LB
B
0
0
0
0
0
↑
0
0
0
0
1
Normal - Channel 2 remote loopback off
Channel 2 remote loopback active
CH. 2 REMOTE LB
B
0
0
0
0
↑
0
0
0
0
0
1
Normal - Channel 3 remote loopback off
Channel 3 remote loopback active
CH. 3 REMOTE LB
B
0
0
0
↑
0
0
0
0
0
0
1
Normal - Channel 4 remote loopback off
Channel 4 remote loopback active
CH. 4 REMOTE LB
B
0
0
↑
0
0
0
0
0
0
0
1
Applies internal TIA-603C emphasis to the Channel
3 audio signal. Set by remote control only.
Disabled
Active
EMP_CH3
B
0
↑
0
0
0
0
0
0
0
0
1
Applies internal TIA-603C emphasis to the Channel
4 audio signal. Set by remote control only.
Disabled
Active
EMP_CH4