106R Basic Systems User Guide

 

    

6190770  (Rev B) 

g) Check the non-return valve

Turn off the compressor on the mains switch and pull out the 

plug .  
Empty the receiver for compressed air by operating the safety 

valve . When the receiver is empty, the reading of the pressure 

gauge is 0 bar . 
Dismount the non-return valve from the receiver .

Disassemble the non-return valve and remove the O-ring (1) 

from the piston .
Clean the non-return valve .
Mount a new O-ring and re-assemble the non-return valve .
Re-install the non-return valve .
Please note that all service must be carried out by a qualified 

person .

Adjustment of pressure switch

The working presure has been preset from the factory, and it is 

normally not necessary to change this . 
However, if it is necessary to change the preset settings, the 

instructions mentioned below should be followed carefully . 

Warning 

The compressor is constructed and approved for a max. 

pressure as stated under Technical Specifications - do not 

adjust to a higher pressure. 

 

Higher working pressure will reduce the lifetime of the 

compressor.

The compressor will stop at max . pressure (stop pressure) and 

start again at min . pressure (start pressure) . The difference 

between max . and min . pressure is the differens pressure . 

Unscrew the lid of the pressure switch . Adjust max . pressure 

adjusting the two springs marked A (clockwise: higher pressure) . 

Adjust the two springs identically . 
Adjust the differens pressure adjusting the spring marked B 

(clockwise: higher differens pressure, start pressure maintained) .

Test of pumping time

The pumping time indicates the condition of the compressor . 
1 .  Check that there are no leaks in the system .
2 .  Empty the air receiver of compressed air so that the 

pressure gauge shows 0 bar .

3 .  Close the filter regulator and check that the drain valve is 

closed . 

4 .  Start the compressor and note the time it takes until it is 

turned off again by the pressure switch . Check that the  

pumping time agrees with the technical specifications for 

the actual compressor system .

Please note that the pumping time in this manual is given for 0 to 

max pressure . 

Important      

Always test the pumping time when cold. If the compressor is 

warm, the pumping time will be considerably longer. 

Summary of Contents for JUN-AIR 106R-25B

Page 1: ...Basic Systems 106R 25B 106R 25BQ2 2x106R 40B 6190770 REV B Registered Trademark Trademark of JUN AIR Inc Copyright 2023 JUN AIR Manufacturing Inc All Rights Reserved WWW JUN AIR COM ISO 9001 CERTIFIED...

Page 2: ...N AIR We reserve the right to make any alterations which may be due to any technical improvements Printed in the USA Table of Contents Operating Manual 4 Technical Specifications 7 Performance Cuves 8...

Page 3: ...air Do not pump combustible liquids or vapors with this product do not use it in or near areas with combustible or explosive liquids or vapors Do not use this unit near open flames CAUTION To prevent...

Page 4: ...re a long lifetime of the compressor it is important that inspection and maintenance is carried out regularly as described in the following Preventive maintenance Activity Weekly Monthly One a year or...

Page 5: ...cal Specifications do not adjust to a higher pressure Higher working pressure will reduce the lifetime of the compressor The compressor will stop at max pressure stop pressure and start again at min p...

Page 6: ...op should not exceed 1 bar d Check the piston gaskets Replace if necessary e Defective valve plate Contact your JUN AIR distributor 4 The motor gets very hot a The ambient temperature is too high If t...

Page 7: ...9 24 8 20 8 Continuous System Output Flow Max Operating Pressure LPM 51 44 2 50 Hz 51 0 60 Hz 44 7 50 Hz 51 0 60 Hz 86 4 92 1 50 Hz 99 1 60 Hz CFM 1 8 1 6 50 Hz 1 8 60 Hz 1 6 50 Hz 1 8 60 Hz 3 1 2 9 5...

Page 8: ...00 110 120 130 0 1 2 3 4 5 6 7 8 9 Flow lpm Duty bar 106R 25B 120 V Air Flow 0 0 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 4 5 5 0 0 20 40 60 80 100 120 Flow CFM Duty psi 106R 25B 230 V Air Flow 60 Hz 50 Hz 30...

Page 9: ...7 8 9 0 20 40 60 80 100 120 Flow CFM Duty psi 2x106R 40B 120 V Air Flow 30 50 70 90 110 130 150 170 190 210 230 0 1 2 3 4 5 6 7 8 9 10 Flow lpm Duty bar 2x106R 40B 120 V Air Flow 0 1 2 3 4 5 6 7 8 9 0...

Page 10: ...USA Electrical Drawing Model 106R 25B SWITCH PRESSURE LINE MOTOR N L1 YELLOW GREEN BROWN BLUE BROWN BLUE 3xAWG16 3xAWG16 Z Compressor Motor W X Ins Capacitor Brown Green Yellow Red Black O r a n g e B...

Page 11: ...Q2 PRESSURE SWITCH Cooler Box L1 N 11 Q1 Q2 Q3 Q4 Orange DRYER Brown Blue White Unloader FAN N L1 Brown White White Red Cable Tie Cable Tie Black e u l B e t i h W d e R Orange Orange Red Brown Black...

Page 12: ...ck L1 N BLUE BROWN YELLOW GREEN 3xAWG18 3xAWG18 3xAWG16 Black White White BLUE BROWN 3xAWG16 BLUE BROWN 3xAWG16 Brown Blue 230V Compressor Chamber Brown O r a n g e Black Red Green Yellow Brown Capaci...

Page 13: ...Y VALVE 5 m Filter COMPRESSOR AIR OUTLET Compressor with Motor Intake Filter TO WASTE Valve Valve Relief Valve Muffler Pneumatic Diagram Model 106R 25BQ2 To Drain Bo le Intake Filter A ercooler Regula...

Page 14: ...al improvements Printed in the USA Pneumatic Diagram Model 2x106R 40B 40 Liter Tank Regulated Pressure Pressure Switch SAFETY VALVE 5 m Filter COMPRESSOR AIR OUTLET Compressor with Motor Intake Filter...

Page 15: ...ice Kit High Pressure K1040 6000 hours or five years 106R Capacitor Replacement Kit K1041 Five years 106R Capacitor Cover K1042 As needed 106R Spare Parts K1043 As needed 106R Retrofit Parts for OF302...

Page 16: ...make any alterations which may be due to any technical improvements Printed in the USA Basic Systems 106R 25B 120 V Feature Diagram 5um FILTER FILTER INTAKE UNDER COVER COMPRESSOR CAPACITOR DRAIN TAN...

Page 17: ...y technical improvements Printed in the USA 106R Basic Systems User Guide 6190770 Rev B Basic Systems 106R 25B 230 V Feature Diagram SAFETY VALVE GAUGE PRESSURE SWITCH PRESSURE PRESSURE GAUGE CHECK VA...

Page 18: ...erations which may be due to any technical improvements Printed in the USA Basic Systems 106R 25BQ2 Feature Diagram NON RETURN VALVE PRESSURE SWITCH VALVE SAFETY GAUGE PRESSURE PRESSURE GAUGE DRYER IN...

Page 19: ...Printed in the USA 106R Basic Systems User Guide 6190770 Rev B Basic Systems 2x106R 40B 120 V Feature Diagram VALVE NON RETURN SILENCER UNDER COVERS REGULATOR 5um FILTER AUTO DRAIN UNLOADER 2X INTAKE...

Page 20: ...make any alterations which may be due to any technical improvements Printed in the USA Basic Systems 2x106R 40B 230 V Feature Diagram SAFETY VALVE GAUGE PRESSURE SWITCH PRESSURE PRESSURE GAUGE CHECK V...

Page 21: ...nglish Symbol Description Caution Please refer to enclosed documentation Warning Hot surfaces Risk of burns Do not touch the compressor head Keep dry Do not expose to rain 55 C 131 F 25 C 13 F Transpo...

Page 22: ...www JUN AIR com Gast Group Ltd Unit 11 The I O Centre Nash Road Redditch B98 7AS United Kingdom Phone 44 0 1527 504040 Fax 44 0 1527 525262 Registered Trademark Trademark of JUN AIR Inc Copyright 2023...

Reviews: