30
13.4.3
UNIT STATUS CHECKING
1# means System 1, 2# means Syestem2
13.4.4
THE MANOMETER INSTUCTION
The manometer is a kind of high pressure equipment, when the heat pump is on, the manometer pointer would point to the
pressure value of refrigerant, the max. value of protection is 42kg/Cm2. When the heat pump is off, the pointer would point
to the same value as actual ambient temperature (e.g. 28
°C) and related air pressure (e.g.18kg/ Cm2).
Please check the manometer when you restart the heat pump after not using for a long time, if it shows
ambient temperature valve is smaller than 2
°C
(
When the ambient temp. is higher than 2°C
)
, it means that refrigerant
has leaked a lot, and you need to confirm with professional engineer as soon as possible.
Code
Description
A1
1# Coil temperature
A2
1# Compressor suction temperature
A3
1# Compressor discharge temperature
A4
Ambient temperature
A5
DHW outlet temperature
A6
Heating/Cooling outlet water temperature
A7
Reserved
A8
1# Compressor current
A9
1# Open steps of EEV
A10
Reserved
b1
2# Coil temperature (double-system unit only)
b2
2# Compressor suction temperature (double-system unit only)
b3
2# Compressor discharge temperature (double-system unit only)
b8
2# Compressor current (double-system unit only)
b9
2# Open steps of EEV (double-system unit only)
E1
History record of error code
E2
History record of error code
E3
History record of error code
E4
History record of error code
E5
History record of error code
E6
History record of error code
ON or Off state
Status interface
Select parameter
M
℃
℃
℃
Return to
homepage
℃
℃
℃