USE AND MAINTENANCE
ENGLISH
-
(1
cod. G19504800
6(77,1*©7$6.&21752//(5ª
3UHVVWKHIROORZLQJNH\RQWKH©
SETTING - USER SETTINGS
ª
SDJHWRDFFHVVWKH©
TASK CONTROLLER
ªSDJH
a
b
c
d
e
<RXFDQSHUIRUPWKHIROORZLQJRQWKLVSDJH
D
Client task controller module ON/OFF
.
attention,: if this is disabled (
OFF
), all the task controller
functions will be disabled and operations such as “
Section
Control
” and “
Variable Rate
” cannot be carried out. If set to
OFF
, the machine geometry descriptor will not be sent to the
TC Server.
E
Section Control ON/OFF
. if
ON
, you can carry out operations
related to the section control (coverage control). If
OFF
,the
automatic section control is disabled and will be managed only
in manual mode.
F
Enable/Disable
the
Variable Rate
function (rate control). If
enabled (
ON
), the system accepts controls from the Server
task controller, setting the seeding target rate setpoint to the
value requested by the TC Server.
G
DDOP Status
: displays the DDOP status; if ON the DDOP has
been recognised by the TC Server, indicating that the device
descriptor object pool has been activated correctly and the
machine geometry has been recognised correctly.
H
Display
Move TC Feedback
. In multi-task controller systems
(multi-instance) it indicates the movement feedback of the TC
function instance. An error has occurred if the feedback remains
set to OFF when the top left key (
Move TC
) is pressed: the TC
Server supports only one TC instance, there are no other TCs
on the ISOBUS network or a generic error occurred
** Note: in order to work with the
Section Control
and
Variable
Rate
properly, “
DDOP Status
” must be set to
ON
(make sure
that this item is ON before carrying out variable rate and section
control operations).
6(77,1*©$,5%$*ª
Note: only in the presence of the AIR SPRING regulator.
3UHVVWKHIROORZLQJNH\IURPWKHPDLQZRUNLQJSDJHWRDFFHVVWKH
©
AIR SPRING
ªSDJH
,QWKH¿UVWHQWU\\RXFDQHQWHUWKHGHVLUHGSUHVVXUHWDUJHWH[SUHV
VHGLQ%DUWRVHQGWRWKH$,5635,1*UHJXODWRU
7KHVHFRQGHQWU\IHDWXUHVWKHDFWXDOSUHVVXUHYDOXH%DU
.H\VDQG±DUHXVHGUHVSHFWLYHO\WRLQFUHDVHDQGUHGXFHWKH
SUHVVXUHWDUJHW
6(77,1*©/2%(&2035(6625ª
3UHVVWKHIROORZLQJNH\IURPWKHPDLQZRUNLQJSDJHWRDFFHVVWKH
©/2%,&2035(6625ªSDJH
a
b
D 3UHVVXUHUHDGE\WKHUHODWLYHVHQVRULQP%DU
E 1XPEHURIUHYVSHUPLQXWH530RIWKHOREHFRPSUHVVRU
.H\VDQG±DUHXVHGUHVSHFWLYHO\WRLQFUHDVHDQGUHGXFHWKH
SUHVVXUHWDUJHW
Summary of Contents for CHRONO 708
Page 4: ...4 cod G19504800 ...
Page 19: ...USO E MANUTENZIONE ITALIANO 7 cod G19504800 J D tensionata non tensionata 600 Kg 3600 Kg ...
Page 59: ...USO E MANUTENZIONE ITALIANO 7 cod G19504800 PAGINA INTENZIONALMENTE BIANCA ...
Page 75: ...75 cod G19504800 Notes ...
Page 76: ...76 cod G19504800 ...
Page 91: ...USE AND MAINTENANCE ENGLISH 1 cod G19504800 J D tensioned not tensioned 600 Kg 3600 Kg ...
Page 131: ...USE AND MAINTENANCE ENGLISH 1 cod G19504800 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 147: ...147 cod G19504800 Notes ...