7.   The hose must be protected from contact with 

hot or sharp surfaces both during use and while 
in storage. The hose assembly should be visually 
inspected prior to each use of the heater. If 
excessive abrasion or wear is evident, or the hose 
is cut, it must be replaced prior to operating the 
heater. The replacement hose assembly may be 
obtained from the manufacturer.

8.  

DO NOT use any pressure regulator or hose 
assembly other than those supplied with the 
appliance. Replacement pressure regulator 
and hose assembly must be those specified. 
Replacement parts may be obtained from the 
manufacturer or your local sales representative.

9.   Installation and use of this appliance must conform 

with local codes and AS/NZS 5601.

10.  This appliance is designed to operate with a 

standard 9Kg propane cylinder with Approved 
Cylinder Connection.

11.  The valve outlet must be maintained in good 

condition. When the cylinder is not in use, be sure 
to cover it with a dust cap. A leak test should be 
performed with soapy water whenever connecting a 
new cylinder. 

NEVER use a match to test for leaks.

12.   The propane cylinder must be turned off whenever 

the appliance is not in use. When the appliance 
is to be stored indoors, the propane cylinder and 
the heater must be disconnected and the cylinder 
stored in accordance with the Standard for Storage 
and Handling of Liquefied Gases.

        IMPORTANT

Storage of an appliance indoors with the cylinder 
attached is only permitted if the size of the cylinder 
complies with AS/NZS 1596; otherwise cylinders 
must be stored outdoors in a well ventilated area.
The guards are fitted to this appliance to reduce 
the risk of fire or injury from burns and no part of it 
should be removed.
This appliance must be protected from exposure to 
rain. Use cover, not supplied.
This appliance must not be operated in the rain.

Any modification to the appliance not described in the  
installation instructions may compromise the safety of 
this appliance. Special concern is as follows:
(1) 

DO NOT bypass thermocouple;

(2) 

DO NOT operate the appliance without 

     the glass guard;
Clothing or other flammable materials should not be 
hung from the heater, or placed on or near the heater. 
The area above the burner may be extremely hot. Direct 
contact with these metal surfaces should be avoided in 
order to prevent burns or clothing ignition.

Screw the coupling nut of regulator into the cylinder valve 
outlet.

POL CYLINDER CONNECTION DEVICE

Type of Gas

Propane

Consumption

32 MJ/h

Operating Pressure

2.75 kPa

Injector Size

1.58 mm

Appliance specifications can be found on the data label.

Summary of Contents for EDEN

Page 1: ... or property damage Read the instructions thoroughly before installing or servicing this equipment FOR OUTDOOR USE ONLY PROPANE GAS The ideal solution for extending the season of outdoor entertaining Creates a stylish and attractive ambience Direct ignition Stainless steel burner for extra long term reliability Complete with hose and POL regulator Efficient and powerful 32 MJ h output Adjustable h...

Page 2: ...nit is serviced and or repaired e Any cleaning agent used on the appliance should be of a non combustible and non corrosive nature Important Safety Rules This appliance must only be used in a well ventilated area 1 This appliance shall not be installed or used indoors in buildings garages or any other enclosed area 2 DO NOT place articles on or against this appliance 3 DO NOT use or store flammabl...

Page 3: ... be stored indoors the propane cylinder and the heater must be disconnected and the cylinder stored in accordance with the Standard for Storage and Handling of Liquefied Gases IMPORTANT Storage of an appliance indoors with the cylinder attached is only permitted if the size of the cylinder complies with AS NZS 1596 otherwise cylinders must be stored outdoors in a well ventilated area The guards ar...

Page 4: ...o all joints and connections of the regulator hose manifolds and valves Bubbles will indicate a gas leak Either tighten the loose joint or have the part replaced with one recommended by our service agent and have the appliance inspected by a certified gas installer If the leak cannot be stopped immediately shut off gas supply disconnect it and have the appliance inspected by a certified gas instal...

Page 5: ...into the burner area away from the square metal cover Position the pebbles evenly around the burner and level out and try to keep the pebbles lower around the square metal cover OUTDOOR GAS FIRE PIT ASSEMBLY 5 KEEP CLEAR IMPORTANT Remove all transit and packaging material from all components before beginning assembly Dispose of in an environmentally friendly manner ...

Page 6: ...brackets again lightly tighten the screws against the glass Now take a top bracket and install this between the 2 glass panels level with the top of the glass and lightly tighten the screws against the glass Repeat this step C until all 4pcs of glass panel are assembled and secured with the 4pcs bottom bracket and the 4pcs top bracket D Once all 4pcs in position tighten the screws so that the glas...

Page 7: ...es Combustible materials are considered to be wood compressed paper plant fibres plastic or other materials that are capable of being ignited and burned SIDE CLEARANCE 500mm TOP CLEARANCE 1000mm 800mm 1125mm 725mm 400mm SIDE CLEARANCE 500mm TOP CLEARANCE 1000mm 530mm 1140mm 740mm 400mm ...

Page 8: ...nce without prior authority from the manufacturer will void any warranty claims Read the installation operating and maintenance instructions thoroughly before installing or servicing this equipment WARNING LIGHTING INSTRUCTIONS WARNING White smoke may appear around the burner during the first minutes of the initial firing 1 Ensure that the control knob is off Slowly open the gas cylinder valve 2 P...

Page 9: ...n which the appliance is used shall comply with the following An enclosure with walls on all sides but at least one permanent opening at ground level and no overhead cover see Example 1 Within a partial enclosure that includes an overhead cover and no more than two walls see Example 2 3 Within a partial enclosure that includes an overhead cover and more than two walls the following will apply At l...

Page 10: ...e call Customer Service Australia Only 1300 174 876 Hours of operation Monday to Friday 8am 5pm EST Do not return to place of purchase Keep your purchase receipt this will be required to make any claims under the 12 month warranty ...