4
After the assembly has been secured, turn on the gas
and check for leaks by brushing a soap and water
solution overall connections.
DO NOT USE this appliance if it is leaking, damaged
or does not operate properly.
If you are unable to correct the leak by tightening
the connections, turn off the gas and contact the
supplier immediately.
Always ensure the appliance is kept away from
flammable materials and the gas cylinder clear
of any heat source. When changing over from an empty
gas cylinder to a full one make sure this procedure
is carried out in a well ventilated location, preferably
outside, away from people and away from any sources
of ignition; such as naked flames, pilot flames, electric
heaters/equipment.
SPECIFICATIONS
Appliance specifications can be found on the data label
attached to the appliance body.
GAS CYLINDER USE & SAFETY
This is a low pressure appliance and must only be used
with the hose and regulator supplied. This appliance
shall only be used with propane gas cylinders certified
to AS 2469. It may be hazardous to attempt to fit other
types of gas containers.
The gas cylinder should be filled by a reputable
gas supplier and visually inspected and re-qualified
at each filling.
Always keep cylinder in an upright position. Always
close the cylinder valve when the appliance is not
in use. Do not subject gas cylinder to excessive heat.
GAS INSTALLATION CODES
• Appliance must be used in accordance with
the installation requirements of your gas supply
authority, or the appropriate installation code
issued by Standards Australia AS 5601.
• Appliances for use with bottled gas are labelled
‘propane gas’.
• Only use on a non-combustible surface.
GAS INSTALLATION CODES
• Appliance must be used in accordance with
the installation requirements of your gas supply
authority, or the appropriate installation code
issued by Standards Australia AS 5601.
• Appliances for use with bottled gas are
labelled ‘propane gas’.
• Only use on a non-combustible surface.
CLEARANCES
Minimum Clearances from combustible materials
must be:
Cylinder 900mm
Wall 900mm
Above 900mm
Below
Never use on a flammable surface.
Only use on a non-combustible surface.
Gas connection is 3/8” SAE
HOSE & REGULATOR SAFETY
The regulator and hose assembly supplied with
the appliance are suitable for propane gas only.
The pressure regulator and hose assembly supplied
with the appliance must be used. Replacement
pressure regulators and hose assemblies must
be those specified by the appliance manufacturer.
Only use the hose assembly supplied with this
appliance for direct connection to the cylinder
“DO NOT USE ADAPTORS”. Check the regulator
“O” Ring periodically for wear or damage and
replace if required.
When connecting the hose and regulator assembly
to the gas cylinder, take care to avoid unnecessary
twisting or kinking of the flexible hose. Maximum
hose length is 1500mm.
GENERAL INFORMATION
NEW LCC27 GAS CYLINDER
AND APPLIANCE CONNECTION
This appliance has been supplied with the new safer
gas cylinder connection Safe Lok LCC27 Type 27
regulator and hose connection.
This connection will only connect to a 4kg or 9kg
gas cylinder with an LCC27 Type 27 cylinder valve.
This connection will NOT connect (screw) to the old
type 21 POL gas cylinder valve.