•  Use outdoors only.
•  Keep children away at all times.
•  CAUTION: Accessible parts may be very hot.  
  Please take care when handling or moving the  
 appliance.
•  Appliance is to be used on a stable, level, flat,  
  non-flammable surface. The appliance should  
  be protected from direct drafts and in a well  
  ventilated place.
•  Only cooking vessels with a minimum diameter  
  of 200mm and a maximum of 300mm are   
  to be used with this appliance.
•  This appliance shall only be used in an above  
  ground open air situation with natural 
  ventilation, without stagnant areas, where 
  gas leakage and products of combustion 
  are rapidly dispersed by wind and natural    
 convection.
•  Take care that the primary air intakes, located  
  on the burner tube of this appliance are not  
  obstructed, or that air flow is restricted by   
  placing items or other appliances close to or  
  adjacent to the inlets.
•  If there is a leak on your appliance (smell of  
  gas), immediately attempt to turn off the    
  cylinder valve. Remove the appliance to a well- 
  ventilated location away from any ignition    
  source. Check for leaks using soapy water. Do  
  not try to detect leaks using a flame.
•  Do not attempt to move or relocate the  

 

  appliance when it is operating, extinguish    
  the burner and allow to cool, disengage the  
  gas cylinder then move the appliance.

IMPORTANT

CHECKING FOR GAS LEAKS

•  Check that all connections are tight and that  
  the gas cylinder connection has been tightened  
  before you turn the cylinder gas valve on.
•  NEVER check for leaks with a flame or pilot  
 light.
•  Using Gas Leak Detection Spray or soapy   
  water, coat all connections, if bubbles appear  
  turn the cylinder gas control off and retighten  
  the connection before re-testing.
•  Inspect the appliance regularly for signs of  
  wear, leaks or incorrect operation.
If symptoms such as flaring of the burner, issues 
with lighting, damages to hoses or connections 
or leaks from seals or gas controls are identified 
do not attempt to repair, return to your authorised 
stockist for service and maintenance.

CHANGING GAS CYLINDER

•  To check if gas remains in the cylinder,  

 

  disconnect from the appliance and hold the  
  cylinder in a vertical position then shake from  
  side to side, if there is a sound or feel of liquid  
  movement inside, the cylinder contains gas.
•  When changing gas cylinders ensure this is  
  conducted outside in a well- ventilated location  
  free from people, animals and ignition sources  
  such as naked flames, pilot lights and electrical  
  equipment with heaters or elements.

Summary of Contents for CS2112

Page 1: ...burners Hose and regulator included Propane ULPG use only Gas certified to Australian Standards For outdoor use only CS2112 CS2123 Gasmate is a registered trademark of Sitro Group Australia Pty Ltd ww...

Page 2: ...ntact SITRO Group for assistance with repairs and spare parts DANGER During operation all surfaces will be extremely hot and should not be touched or handled Do not use the appliance if it is leaking...

Page 3: ...to move or relocate the appliance when it is operating extinguish the burner and allow to cool disengage the gas cylinder then move the appliance IMPORTANT CHECKING FOR GAS LEAKS Check that all connec...

Page 4: ...re this procedure is carried out in a well ventilated location preferably outside away from people and away from any sources of ignition such as naked flames pilot flames electric heaters equipment GE...

Page 5: ...CK APPLIANCE FOR ANY DAMAGE Inspect appliance parts as you proceed Contact your supplier for assistance regarding replacement of any damaged or missing parts Do not assemble or operate a appliance tha...

Page 6: ...spray or soapy water on all connections to check for leaks If a leak is detected turn the valve off retighten all connections and retest LIGHTING THE COOKER 1 Turn the gas cylinder valve on in an anti...

Page 7: ...liance clockwise to the OFF position Pic 8 CARE INSTRUCTIONS As with all appliances proper care and maintenance will keep them in top operating condition and prolong their life By following these clea...

Page 8: ...cludes an overhead cover and no more than two walls C Within a partial enclosure that includes an overhead cover and more than two walls the following must apply 1 At least 25 of the total wall area i...