MGC Dock
User’s Manual
V1.5
Port able gas det ect or s y ou can count on.
7 of 15
Download each detector’s logs
Bum p, Calibrat e, or hibernat e as r equest ed
Record t he t est t o t he USB m em or y
Troubleshooting Failures
1.
I nspect t he det ect or sensor and beeper cavit ies and clear any obst ruct ions.
2.
Clean t he sm all I R com m unicat ion window locat ed on t he t op of t he det ect or.
3.
Verify t he gas bot t le is not em pt y .
58L bottles are “full” at 500 PSI
; 11 6L at 1000
PSI .
4.
Try r elocat ing t he Clip Dock aw ay fr om bright light sour ces, w hich m ay int erfer e w it h
I R com m unicat ion bet w een t he Clip Dock and t he det ect or s.
5.
I f a m onit or has failed 3 aft er t hr ee t est at t em pt s, please cont act Gas Clip
Technologies.