background image

 

 
 
 
 Corporate Headquarters

 

 

 

GarrettCom, Inc.

 

   

                             

 

ww

m  com

w  GarrettCo

.

.

www  GarrettCom  com

.

.

47823 Westinghouse Dr. 
Fremont, CA  94539 
Phone  (510) 438-9071 
Fax  (510) 438-9072 
Website:  http://www.GarrettCom.com 
 
email  [email protected]
 

 
 
 

                       

 

 

 
  
 

        

 Magnum ES42 Edge Switches 

         

  

  

 

 

 

Installation and User Guide

$5.00 USD

Summary of Contents for Magnum ES42 Series

Page 1: ...ww m com w GarrettCo www GarrettCom com 47823 Westinghouse Dr Fremont CA 94539 Phone 510 438 9071 Fax 510 438 9072 Website http www GarrettCom com email support garrettcom com Magnum ES42 Edge Switche...

Page 2: ...rk of Telcordia Technologies UL is a registered trademark of Underwriters Laboratories Important The Magnum ES42 Series 10 100 Mb s Edge Switches contains no user serviceable parts Attempted service b...

Page 3: ...se interference to radio communication It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules...

Page 4: ...ettCom com Contacting GarrettCom Inc Please use the mailing address phone and fax numbers and email address listed below GarrettCom Inc 47823 Westinghouse Dr Fremont CA 94539 Phone 510 438 9071 Fax 51...

Page 5: ...Product Description 13 2 3 Frame Buffering and Latency 22 2 4 Features and Benefits 25 2 5 Applications for ES42 Series Edge Switches 28 3 0 INSTALLATION 36 3 1 Locating the Edge Switch Unit 36 3 2 MC...

Page 6: ...e Fiber Optic 52 3 8 5 Power Budget Calculations for ES42 Series Fiber Media 53 3 8 6 Connections to NICs which support Auto Neg RJ 45 ports 55 4 0 OPERATION 56 4 1 Dual Speed Functionality and Switch...

Page 7: ...ing Information 67 APPENDIX A WARRANTY INFORMATION 69 Revisions Rev A 05 05 Minor updates on MDIX Auto cross Rev A 02 05 Initial release of this user manual for ES42 Edge Switches GarrettCom Inc reser...

Page 8: ...ps Data Rate 10 Mbps Network Standards 100Mb Ethernet IEEE 802 3u 100BASE TX 100BASE FX 10 Mb Ethernet IEEE 802 3 10BASE T Auto sensing for speed IEEE 802 3u Packet Processing Between Domains Filter a...

Page 9: ...d 2 allow to flush the internal address buffer and qualify to use with S Ring and RSTP for faster recovery in ring topology Maximum Ethernet Segment or Domain Lengths 10BASE T Unshielded twisted pair...

Page 10: ...C to 75 C Long term per agency tests UL 58 F to 212 F 50 C to 100 C Short term per IEC Type tests Storage Temperature All models 40 F to 160 F 40 C to 85 C Cold Start ES42H to 20 C ES42P to 40 C Ambi...

Page 11: ...Hi 5 8 oz 165g Pd and Pi 7 9 oz 225g Cooling Method Convection on the office model The hardened H factory floor and premium P temperature un controlled location models have closed cases to withstand...

Page 12: ...urrent i e 100mA to 500mA When connected to a 48V centralized DC source these products shall be provided with a Listed 5 A DC fuse in the supply circuit AC POWER SUPPLY using an external power adapter...

Page 13: ...s International Hi models Factory floor temperature rated Input IEC 320 connector on the 100 240vac 47 63Hz external power adapter Requires a user supplied power cord Output 12vdc 1 25Amps Temperature...

Page 14: ...60V DC ground Note DUAL SRC 24KIT For ES42H or P 24VDC unit only sold separately See 3 6 Power Consumption See Section 3 6 Note 1 the 12V DC jack can be used for dual source DC input using an AC adapt...

Page 15: ...100Base FX with a fiber flavor choice of multimode SC ST LC or MTRJ or single mode SSC SSCL SST or SLC connectors By default factory settings is at Full duplex on fiber ports LED Indicators Front POW...

Page 16: ...Time Between Failure MTBF over15 years Telcordia Bellcore Method Agency Approvals and Standards Compliance UL Listed UL 60950 cUL CE Emissions meets FCC Part 15 Class A NEBS L3 and ETSI compliant H an...

Page 17: ...external AC power supply ES42H 2ff Hd Hi Hardened H four RJ 45 two 100Mb Fiber port for factory floor 25 to 60C using a direct DC 8 15VDC and or external AC hardened power supply included ES42H 2ff 12...

Page 18: ...connector 20km SLC 100Base FX SLC single mode fiber optic with LC type connector 15km MTRJ 100Base FX MTRJ multi mode fiber optic with MTRJ type connector 2km SLC 100Base FX SLC single mode fiber opti...

Page 19: ...prior to installing this product notify the carrier immediately of any damage which you believe occurred during shipment or delivery Inspect the contents of this package for any signs of damage and en...

Page 20: ...ES42 Series Switches are designed as an Ethernet edge solution in heavy duty industrial military and un controlled temperature applications as well as an economical solution for the growing requiremen...

Page 21: ...outdoor models The breadth of models and flavor of fiber port types offers the best price to value ratio for each user and installation The compact package is ideal for network edge installations and...

Page 22: ...1 0 1 0 0 12 VDC 1 AMP 10 100 10 100 1 0 F O R 1 0 0 A O R L K A C T L K A C T P W R 1 2 3 4 5 6 PORT PORT 1 2 3 4 5 6 Magnum E 42 S E d g e S w i t c h The Magnum ES42 regular package units are for o...

Page 23: ...d Magnum ES42 models as shown in Fig 2 2 a b c units are for office and wiring closet environments and use an external AC power supply A ventilated metal case for convection cooling is featured Ambien...

Page 24: ...does not have options for Alarm and DC power 1 0 1 0 0 12 VDC 1 AMP 1 0 F O R 1 0 0 L K A O R L K A C T A C T P W R 1 2 3 4 5 6 PORT PORT 1 2 3 4 5 6 AL A R M 10 100 TX RX FH2 10 100 RX TX FH2 H a r...

Page 25: ...nting DIN Rail or rack mount tray The ORANGE labeled Magnum ES42H hardened units shown in Fig 2 2d e are designed for factory floor Industrial applications Using special thermal techniques and a seale...

Page 26: ...tion to a Premium rated AC power option and jack terminals for internal DC power choices at 8 to15V 24V or 48V DC are included When used outdoors the ES42P should be protected from rain Mounting optio...

Page 27: ...rnal AC or internal DC power are available Ambient operating temperature is between 40 C to 75 C depending on the power source used Storage temperature rating is between 40 C to 85 C All the premium a...

Page 28: ...operating status of ports are mounted on the top and front for extra viewing advantage while rack mounted For each port there are Link and Activity LK ACT LED s on the top indicating that the media c...

Page 29: ...Buffering and Latency The Magnum ES42 Series Edge Switches are store and forward switches Each frame or packet is loaded into the Switch s memory and inspected before forwarding can occur This techniq...

Page 30: ...ailable for good packets when the traffic load is greatest To minimize the possibility of dropping frames on congested ports each Magnum ES42 Series Edge Switch dynamically allocates buffer space from...

Page 31: ...ets out to the devices sending packets to cause flow control This tells the sending devices to temporarily stop sending traffic which allows a traffic catch up to occur without dropping packets Then n...

Page 32: ...arding the latency is 5 microseconds plus the packet time of 100Mb 2 4 Features and Benefits Full 100Mb or 10 Mb switching services for high performance Ethernet Magnum ES42 Series Switches provide Fa...

Page 33: ...rom each domain that are needed on the other domains Internal address tables are self learning enabling users to change port connections or 10 100 domains without affecting operations Two sets of LEDs...

Page 34: ...ernal AC and internal DC power supply Magnum ES42 Series of Edge Switches can be installed in small spaces in cabinets on table tops in racks walls or DIN Rail mounted and in trays such as the Magnum...

Page 35: ...rdiness models Yellow office wiring closet Orange Hardened Red Premium rated outdoor and hundreds of port type combinations Magnum ES42 Series Edge Switches fit very well in almost any environment to...

Page 36: ...ber on Ports 1 and 2 enable easy expansion for the on going demand of Ethernet networks The 10 100Mbps auto negotiating MDIX copper ports and the breadth of 100Mbps fiber ports enable easy interfacing...

Page 37: ...tch ver 2 1 0 1 00 12 VD C 1 A MP 10 F O R 100 A OR LK AC T LK AC T PW R 1 2 3 4 5 6 PORT PORT 1 2 3 4 5 6 ALARM 10 100 TX RX FH2 P r e m i u m Magnum E 42 S E d g e S w i t c h 10 100 RX TX FH2 Magnu...

Page 38: ...he ES42 s six ports in a small reliable enclosure provide an effective solution to for transferring real time transactions from the store to the storage device in the control room The easily deployabl...

Page 39: ...enter The ES42H and CS14H provide a good solution with their multiple options and hardened features The two Fiber ports on the Edge switches are ideal for secure data communications over long distance...

Page 40: ...FH 2 P r e m i u m M a gnum E 42 S E d g e S w i t c h 10 100 RX TX F H2 10 100 12 VDC 1 AMP 10 F OR 100 A O R LK AC T LK AC T PW R 1 2 3 4 5 6 PORT PORT 1 2 3 4 5 6 A L A R M 10 100 TX RX FH 2 P r e...

Page 41: ...zoom PTZ controlled through an Ethernet copper port The premium Edge Switches provide two fiber segments for secure long distance 2 40km communication while being installed in temperature un controll...

Page 42: ...T X FH2 iMac iMa c iMac ES42p in a Outdoor application CCTV Camera CCTV Camera CCTV Camera CCTV Camera CCTV Camera CCTV Camera 1 0 1 0 0 12 V DC 1 AMP 1 0 F OR 10 0 A O R LK AC T LK AC T PW R 1 2 3 4...

Page 43: ...cation mountings power supply options and media connection Secure attachment of clips for panel 3 1 Locating the Edge Switch Unit All the ES42 Series Switches operate in transparent half and full dupl...

Page 44: ...atively metal mounting clips and screws are included for a rugged and secure mounting in any orientation Installation of the Magnum ES42 Series Edge Switches is a simple procedure The installation loc...

Page 45: ...42 Series Switches For 19 rack mounting of Magnum ES42 series Edge Switches a rack mount tray is available the MC14 TRAY The Edge Switches are mounted with the DC power jack in the back with the fiber...

Page 46: ...n the bottom front hold the Edge Switches firmly in place The beveled top edge of the units permits the LEDs of each unit to be viewed for operational status even when the units are very close togethe...

Page 47: ...ia Edges each with their power input plugged into the built in common AC power supply in the rear area of the tray AC PS units that come with the office models of the Edge Switch s are not used Becaus...

Page 48: ...hown alongside the DIN Rail MC2 bracket here The metal DIN Rail mounting hardware is optional and needs to be ordered as a separate item e g Model DIN RAIL MC2 It comes with four screws to attach the...

Page 49: ...minal 12VDC input version The extended temperature H and P versions are used for heavy duty industrial applications The 12V DC power input jack has a plug of 2 5mm center ve with 6 ft cord All the AC...

Page 50: ...jack is also present Detail information about the 12 VDC the 24V DC and the 48V DC is provided in the Technical Specifications Section 1 1 The various models of DC power type and extended ambient tem...

Page 51: ...ilt in screw terminals for secure attachment of the power input leads Three DC power models support a range of power input types The three DC power input terminal block choices are for use with 12VDC...

Page 52: ...P models with 24VDC support the Dual Source 24V input option An external Dual SRC 24KIT SHOWN AT RIGHT and sold separately or a customer supplied equivalent can be used to input 24VDC power to the ES...

Page 53: ...ground wire connection to the ES42H chassis Input Voltage 12VDC 24VDC 48VDC Input current 12VDC 8 15VDC Alarm Contact Terminal 12V 8 15VDC 24VDC 10 36VDC 48VDC 30 60VDC 12V or 24V 10 30VDC 12V 8 15VD...

Page 54: ...ES42H Edge Switch as shown in the Figure The DC terminal block on the Magnum ES42H is located on the left side of the unit and is equipped with three 3 screw down lead posts The power terminals are i...

Page 55: ...f the incoming power supply and figure out the ve potential lead or ve potential lead The more ve potential lead will connect to the post labeled ve and the rest to the ve The GND can be hooked up at...

Page 56: ...ndwidths as compared to copper wiring Media IEEE Standard Connector Twisted Pair CAT 3 or 5 10BASE T RJ 45 Twisted Pair CAT 5 100BASE TX RJ 45 Fiber Multi mode 100BASE FX ST SC Fiber Single mode 100BA...

Page 57: ...f the port Note that even though the connector is shielded either unshielded or shielded cables and wiring may be used 2 Connect the other end of the cable to the corresponding device 3 Use the LINK L...

Page 58: ...fiber optic cable is coded using color bands at regular intervals you must use the color coded strand on the associated ports at each end of the fiber optic segment 3 Connect the Transmit TX port lig...

Page 59: ...4 Connecting Single Mode Fiber Optic When using single mode fiber cable be sure to use single mode fiber port connectors Single mode fiber cable has a smaller diameter than multi mode fiber cable 9 1...

Page 60: ...er Output Power and PR Receiver Sensitivity Worst case OPB OPB 1dB for LED aging 1dB for insertion loss Worst case distance Worst case OPB in dB Cable Loss in dB Km where the Cable Loss for 62 5 125 a...

Page 61: ...ulti mode 2 0 4 1310 62 5 125 50 125 20 23 5 31 31 9 0 5 5 2 5 2 0 14 12 5 4 ES42 SSC 100Mb FX Single mode 20 0 4 1310 9 125 15 31 14 28 17 5 35 ES42 MTRJ 100Mb FX Multi mode 2 0 4 1310 62 5 125 50 12...

Page 62: ...g loss Insertion loss safety factor 3 8 6 Connections to NICs which support Auto Negotiation RJ 45 ports The copper ports of Magnum ES42 Sereis Edge Switches will function properly with NICs Network I...

Page 63: ...capability The switched RJ 45 ports are full or half duplex auto sensing for mode and speed and auto cross for plug polarity See Section 4 2 When the connected device is 10 Mbps the ES42s obeys all t...

Page 64: ...e network from processing them A packet whose destination address is on another port segment will be forwarded to the appropriate port and will not be sent to the other ports where it is not needed Pa...

Page 65: ...42 to other unmanaged switches legacy hubs managed switches media converter etc Please note that there can be conditions with managed switches where the switch manager fixes the port settings via soft...

Page 66: ...ble should similarly advertise respond Both sides will agree to the speed and mode to be used per the IEEE 802 3u standard Depending upon the devices connected this will result in agreement to operate...

Page 67: ...device The Link ports are also represented by LA1 LA2 LA3 LA6 Steady On or steady Off indicates no Receive Activity 10 100 Steady ON for 100Mb speed OFF for 10Mb speed per port copper ports F H FH1 F...

Page 68: ...ion is present the terminal block for Alarm Contacts is part of the Power Input panel in the Magnum ES42s case The DC power input connection is in the same panel The NC Alarm Contact is held close whe...

Page 69: ...Ethernet products are designed to provide reliability and consistently high performance in all network environments The installation of Magnum ES42 Series 10 100 Mb s Switches is a straightforward pro...

Page 70: ...Assistance 1 If difficulty is encountered when installing or operating the unit refer back to the Installation Section of the applicable chapter of this manual Also check to make sure that the various...

Page 71: ...er port is functional and working 4 Make sure that an AC power cord is properly attached to each Magnum ES42 Series unit Be certain that the AC power cord is plugged into a functioning and appropriate...

Page 72: ...unknown contact GarrettCom Inc by fax phone or email support garrettcom com for assistance 5 2 When Calling for Assistance Please be prepared to provide the following information 1 A complete descrip...

Page 73: ...workstations terminals and printers plus the various network media types being used along with diagram of network setup 4 A record of changes that have been made to your network configuration prior t...

Page 74: ...rson Name of your company institution Your shipping address Product name Serial Number or Invoice Number Packing List Number or Sales Order Number Date of installation Failure symptoms including a ful...

Page 75: ...arrettCom reserves the right to charge for the testing of non defective units under warranty Testing and repair of product that is not under warranty will result in a customer user charge 5 4 Shipping...

Page 76: ...ofoam popcorn type packing material This material may cause electro static shock damage to the unit 2 Clearly mark the Return Material Authorization RMA number on the outside of the shipping container...

Page 77: ...rge other than shipping and handling provided that the product is returned pre paid to GarrettCom This warranty will not be effective if in the opinion of GarrettCom the product has been damaged by mi...

Reviews: