Post Installation Configuration & Checkout
190-01499-02
GTX 3X5 Transponder TSO Installation Manual
Rev. 9
Page 6-2
6.3
Configuration Mode and Settings
NOTE
Screenshots are for illustrative purposes only. They do not imply the shown setting(s) should be used in
any installation.
System and interface settings are shown in configuration mode and are unique to the GTX 3X5 installation. The
configuration settings are stored in internal memory. If connected, the configuration module stores configuration
settings. The optional GAE module operates as a configuration module. In this section, configuration instructions
are for panel mount units. To configure remote units refer to section 6.11.
To enter configuration mode on a panel mount unit, push and hold
ENT
and apply power.
• Push and hold
OFF
until the unit powers off to exit configuration mode.
• Push
FUNC
to cycle through the group pages.
• Push
8
or
9
to scroll up or down on the page without an active field selected.
• Push
CRSR
to access items on the page.
• Push
8
or
9
to cycle through the selections of an item on the page.
• Push
ENT
to move within the page with a field highlighted or to accept setting.
• Push
CLR
to move to previous selection on the page.
• Push
FUNC
to exit the page.