Garmin G5 Install Manual & Pilot's Guide
190-02072-00 Rev. E
79
Unit Installation
Installation Manual
Pilot's Guide
Appendix
Index
4)
At each calibration point the display will present a screen indicating the
pressure altitude to set. Once the altitude is set, select Ready to calibrate
this pressure.
5)
During the calibration at each pressure, the pressure must be held constant
for 30 seconds for the calibration step to be successful. The calibration may
be cancelled at any point should the test setup require adjustment before
repeating. A progress screen will be displayed showing the status of the
test.
6)
Select Done when the static pressure calibration is successfully completed.
1.8.4.5.5 C
aLiBration
P
roCedure
d: m
aGnetometer
u
nit
o
rientation
1)
Select the Magnetometer Configuration page.
2)
Ensure that the Status field displays Data Valid.
3)
Select the Orientation of the GMU 11 in the installation using the on-screen
instructions as a guide.
Figure 1-49 Select Magnetometer Orientation
4)
Ensure that the correct orientation is now displayed on the Magnetometer
Configuration page.