To deploy the M10GxxBP modular tap system into your network, simply:

 

Carefully unpack and inspect the tap modules and system chassis.

 

Insert and fully seat the M10GxxBP modules into the M10Gxxxx chassis and secure modules using both screws.

 

Install the tap and chassis assembly into any available 1U slot of a network rack and secure it with rack mount screws.

 

Connect the power supply to the M10GxxBP and plug it into an available power source and turn on the power switch. Note: 

A VLAN message on the LCD screen is normal.

 

Utilizing the CLI or GUI, configure the M10GxxBP for the operating mode of your choice (default is bypass mode).

 

Remove the power supply to the M10Gxxxx chassis temporarily.

 

Using standard Ethernet cables, connect NETWORK ports [A] and [B] of the M10GxxBP between the two live network devices where you would otherwise deploy an inline 
appliance or sensor (for example: IPS or DLP). Verify network traffic is flowing, confirming that network cabling is correct.

 

Connect MONITOR ports [A] and [B] to the inline IPS/DLP appliance or other tools for traditional breakout or aggregated traffic monitoring.

 

Connect the power leads to the M10Gxxxx chassis power supplies and plug it into an available power source. Turn on the chassi s power switch. Note: 

A VLAN message on the 

LCD screen is normal.

Notes:   *  Fiber is always 10Gbps speed. Other operating modes may be desired for monitoring and may be configured using the CLI or GUI.

              *  If you wish to replace one of the modules in a chassis without shutting the power to the entire chassis, you need to remov e power to the module that you wish to replace                        

       through the CLI using the  power_off  command.  See Sub-paragraphs 6.56.8 and 6.56.9 on page 69 of the User Guide.

M10GxxBP Series Modular Tap

Installation Guide

AC Power Input

DC Power Input

Fiber Active Bypass Modules

IP & Serial Management

GN D

N EG

PO S

Pg 1

Ver 2.2.1

Summary of Contents for M10G BP Series

Page 1: ...deploy an inline appliance or sensor for example IPS or DLP Verify network traffic is flowing confirming that network cabling is correct Connect MONITOR ports A and B to the inline IPS DLP appliance...

Page 2: ...of network traffic simultaneously Breakout Separates data flows for half duplex directional monitoring Ideal when utilization is very high and packet loss is not an option SPAN or Regenerate Allows us...

Page 3: ...M10GxxBP Tap Module Operating Modes Bypass auto Live Network Sensor Online M10GxxBP Series Modular Tap Installation Guide Bypass active Live Network Sensor Offline Pg 3 Ver 2 2 1...

Page 4: ...ss Tap IPS Appliance Figure 2 Active Bypass IPS Offline Data and Heartbeats Copied to Sensor A B A B 1 2 Garland Bypass Tap IPS Appliance Figure 3 Passive Bypass Power Failure Network Interfaces Reneg...

Page 5: ...Live Network M10GxxBP Tap Module Operating Modes Aggregate TAPA M10GxxBP Series Modular Tap Installation Guide Monitor Ports Live Network Monitor Ports Breakout TAP TAP TAPA Pg 5 Ver 2 2 1...

Page 6: ...0GxxBP Tap Module Operating Modes Aggregate TAPAI12 M10GxxBP Series Modular Tap Installation Guide Monitor Ports Live Network Monitor Ports Breakout TAPI12 Dual Packet Injection Dual Packet Injection...

Page 7: ...ap Module Operating Modes Aggregate TAPAI2 M10GxxBP Series Modular Tap Installation Guide Monitor Ports Packet Injection MON B Live Network Aggregate TAPAI1 Monitor Ports Packet Injection MON A TAPAI1...

Page 8: ...M10GxxBP Series Modular Tap Installation Guide Web Interface Orientation Default Login Credentials admin gtadmin1 Pg 8 Ver 2 2 1...

Page 9: ...M10GxxBP Series Modular Tap Installation Guide Web Interface Orientation Pg 9 Ver 2 2 1...

Page 10: ...M10GxxBP Series Modular Tap Installation Guide Web Interface Orientation Pg 10 Ver 2 2 1...

Page 11: ...M10GxxBP Series Modular Tap Installation Guide Web Interface Orientation Pg 11 Ver 2 2 1...

Page 12: ...M10GxxBP Series Modular Tap Installation Guide Web Interface Orientation Pg 12 Ver 2 2 1...

Page 13: ...M10GxxBP Series Modular Tap Installation Guide Web Interface Orientation Pg 13 Ver 2 2 1...

Page 14: ...M10GxxBP Series Modular Tap Installation Guide Web Interface Orientation Pg 14 Ver 2 2 1...

Page 15: ...M10GxxBP Series Modular Tap Installation Guide Web Interface Orientation Pg 15 Ver 2 2 1...

Page 16: ...M10GxxBP Series Modular Tap Installation Guide Serial Console Cable Pinout Pg 16 Ver 2 2 1...

Page 17: ...y 0 0 0 0 M10GxxBP system administrators may set the Ethernet management port s IP address parameters with the following commands Set_ip Configures an IPv4 address Set_netmask Configures an IPv4 subne...