Installing Shelf To Backguard
Note: Shelf may be installed before or after installing the
backguard to the range .
1 . Loosen 4 bolts on the front of the backguard
approximately 1/4” (6mm) .
2 . Align the 4 slotted holes on the back of the shelf with the
4 bolts on the backguard .
3 . Slide the shelf downward until the 4 bolts are engaged in
the slotted portion of the keyhole .
4 . Tighten the 4 bolts to secure the shelf .
5 . On 60” units only, install a sheet metal screw though the
hole in the underside of the shelf into the backguard and
tighten .
SHELF
BACKGUARD
MOUNTING
BOLTS
SHEETMETAL
SCREW
Backguard With High Shelf, Salamander Or
Cheesemelters Mounting Instructions
1 . Rear of the range must be easily accessible .
2 . Please refer to the installation instructions included with
the salamander or cheesemelter for further instructions
on these units .
3 . For the backguard or high shelf, place on the rear of the
range, slipping the support brackets into the openings in
the main body sides .
4 . Securely fasten the support brackets to the burner box
sides with (4) sheet metal screws provided .
Upright
Main Body
Side
Sheet Metal
Screws (4 Req'd)
Ventilation Air
The following notes are intended to give general guidance .
For detailed recommendations, refer to the applicable
code(s) in the country of destination .
Proper ventilation is critical for optimum performance . The
ideal method of ventilating open-top equipment is the use
of a properly designed canopy that should extend six inches
(152 mm), beyond all sides of the appliance(s) and six feet, six
inches (1981mm) above the floor .
A strong exhaust will create a vacuum in the room . For an
exhaust vent to work properly, replacement air must be
equal to the amount of air exhausted . An imbalance between
exhaust and replacement air can cause degradation in the
appliance’s performance .
All gas burners and pilots need sufficient air to operate . Large
objects should not be placed in front of the appliance(s) that
would obstruct the flow of air into the front .
Statutory Regulations
The installation of this appliance must be carried out by
a competent person and in accordance with the relevant
regulations, codes of practice and the related publications of
the country of destination .
The installation must conform to the National Fuel Gas Code
ANSI Z223 .1, or latest edition, NFPA No .54 - latest edition/or
local code to assure safe and efficient operation . In Canada,
the installation must comply with CSA B149 .1 and local
codes .