Version 1.6 Page 148 of 159
Garland Technology reserves the right to make changes without further notice to any products or data herein to improve reliability, function or design.
Confidential -This document is
Garland Technology
.'s property. This document may not be copied, duplicated and transferred to electronic or mechanized
media or used for any other purpose, including any part thereof or attachment thereto, except as authorized in advance and in writing by
Garland Technology.
CAUTION:
The battery requires special handling at end-of-life. The battery can explode or cause burns if
disassembled, charged, or exposed to water, fire or high temperature. After replacing the battery,
properly dispose of used battery according to instructions.
There is a risk of explosion if the battery is replaced by an incorrect type. Ensure to replace the
battery with the same type.
To avoid the possibility of electric shock, all power cords must be disconnected from the switch
before starting this procedure.
CAUTION:
The fiber optic ports contain a Class 1 laser device. When the ports are disconnected, always cover them
with the provided plug. If an abnormal fault occurs, skin or eye damage may result if in close proximity to
the exposed ports.
Remove and save the fiber optic connector cover.
Insert a fiber optic cable into the ports on the network adapter bracket as shown.
10.1.1 Safety considerations for the M40GBP rack mounting:
A. Verify that the maximum operating ambient temperature inside a rack assembly does not exceed
50
C.
B. Verify that a sufficient clear space is provided around the M40GBP unit to allow sufficient amount of
air flow for safe operation of the product. Keep 25 mm clearance on the sides of the unit.
C. Serious injury could result due to improper handling and uneven mechanical loading. Use proper
techniques to mount and secure to the rack to avoid uneven mechanical loading.
D. An external circuit breaker rated max. 20A should be provided in the building installation (end user's
responsibility).
E. Verify that the M40GBP unit is reliably connected to protective grounding. Connect the product only
to a grounded type socket-outlet in the building installation or in a rack. Use the grounding stud on the
rear panel to connect the product to the rack.