background image

ww.oberdorfer-ppumps.com

PHONE  800-4448-11668;  (315)  437-00361

FAX  (315)  463-99561

FEATURES

Body: Durable Cast Bronze 

Cam: Machined-in for improved impeller life

oprene

Shaft: Stainless Steel

Wear Plate: Replaceable / Reversible

Shaft Seal: Mechanical - Carbon/Ceramic/Buna

Macerator: Replaceable

Vacuum Switch:  Dependable Spring Loaded Rubber 

Diaphragm (manual re-set)

Ports: 1 1/2" Male NPT Inlet  and OD Barb for 

2" ID Hose, 1" Female NPT Outlet with 
OD Barb for 1 1/2" ID Hose

Weight: Portable 

VARIATIONS AVAILABLE

MODEL NO.

DESCRIPTION

406M-04

Pump Head with Standard Neoprene 
Impeller

406M-07

Pump Head with Buna Impeller

406M-04N26

Pump with 1725 RPM 1 HP 1 Phase AC 
ODP Motor

406MK-04N26

Pump with 1725 RPM 1 HP 1 PhaseAC 
ODP Motor, Vacuum Switch and 8’ power 
cord and plug 

406M-04N95

Pump with 1725 RPM 1 HP 3 Phase AC 

ODP Motor

406M-04N75

Pump with 1725 RPM  1 HP 12 VDC 

TEFC Motor

406M-04N76

Pump with 1725 RPM  1 HP 24 VDC 

TEFC Motor

406MG-03UGY

Pump with  3000 RPM 3 HP Gas Engine

406MK-04

Pump Head with Vacuum Switch

APPLICATIONS

MARINE:      

Sewage Transfer, Dockside Pump-out, 
Holding Tank Pump-out

MOBILE:

Campers, Campsites, Trailers, Mobile 
Homes, General Utility,Emergency

INSTALLATION

Macerator Pump Model 406M

can be configured to run in either

rotation. However once the configuration is set, it becomes a uni-
directional pump. Given the macerator feature, the pump will not
function in both rotating directions during operation.  Model 405M
can be converted to 406M using macerator conversion kit 10827. 

Vacuum Switch Option

is intended to be used as a safety device

to protect pump and motor from damage caused by dry running
conditions. Switch must be mounted on the suction side of the
pump in order to sense a break in vacuum. Pump housing has
properly positioned convenient connection points for this pur-
pose. When the switch senses vacuum falling below 1 1/2" mer-
cury, it will open/break  the power circuit to the single-phase 115V
/230V  AC motor. 

Caution:

For DC motor operation, the Vacuum Switch is only rated

32-115-230V up to  1/2 HP. It is not designed for direct use with 1 HP
12VDC or  1 HP 24 VDC motors.     For Three Phase motors,  the
vacuum switch must be wired, using a control circuit to actuate an
independent relay. Do not attempt to use the switch to disrupt two of
three power legs directly to three phase motors. 

Suction Plumbing

considerations are important to assure adequate

fluid flow to the pump. Avoid collapsed or kinked hose conditions by
using pipe or reinforced hose. Avoid unnecessary bends or elbows.

Pump Heads with Vacuum Switch (406MK-04) 

are Factory supplied

with Vacuum Switch mounted in the
"Factory Supplied" CCW rotation ori-
entation  shown on pg.3.  If  reverse
rotation is desired,  follow the dia-
gram to reposition the switch 14 ,
pipe nipple 15,  pipe plug 16, pick
screw 27, port plug 17, and plate 20.
Note that there is a notch in plate 20
that is always oriented towards dis-
charge. Follow instructions for
mounting pump head to motor and
the wiring diagram to interface the
vacuum switch.

406MK-04N26 is supplied in the  "Factory Supplied" CCW rotation ori-
entation shown on pg.3 and with the vacuum switch prewired to the 1
HP motor for 115 V operation. A convenient 8 ’ long power cord and
plug is provided.

406MK-04N26

406MG-03UGY

Installation, Operation, and Maintenance Instructions

Sewage Transfer/Macerator Close Coupled Rubber Impeller Pumps

406M

IOM

Part No.

1

2

3

4

5

6

7

8

9

10

11

12

13

Motor

Handle

Adapter

Screw

Collar

Key

Shaft

Key

Key

W asher

Seal

Screw

Body

Assy.

1 Reqd

1 Reqd

1 Reqd

4 Reqd

1 Reqd

1 Reqd

1 Reqd

1 Reqd

1 Reqd

1 Reqd

1 Reqd

1 Reqd

1 Reqd

406M-04

---

---

7459

5411

5886

6845

7519

5475

6947

6631

32230

5595

7040

406M-04N26

7055

9773

7459

5411

5886

6845

7519

5475

6947

6631

32230

5595

7040

406MK-04N26

7055

9773

7459

5411

5886

6845

7519

5475

6947

6631

32230

5595

7040

Part  No.

14

15

16

17

18

19

20

21

22

23

24

25

26

Vacuum

Nipple

Pipe

Pipe

Impeller

Gasket

Plate

W heel

Screw

Cover

Screw

W asher

Jam Nut

Switch

Plug

Plug

1 Reqd

1 Reqd

2 Reqd

1 Reqd

1 Reqd

2 Reqd

1 Reqd

1 Reqd

1 Reqd

1 Reqd

4 Reqd

1 Reqd

1 Reqd

406M-04

---

---

7043

7189

6603

7188

7101

7075

6437

7100

8229

7255

7256

406M-04N26

---

---

7043

7189

6603

7188

7101

7075

6437

7100

8229

7255

7256

406MK-04N26

7046

7050

7043

7189

6603

7188

7101

7075

6437

7100

8229

7255

7256

Part No.

27

28

29

30

31

32

33

34

*Repair Kits contain items

Pick

Cord

Terminal

W ire

W ire

W asher

Screw

Cord

Repair

11, 18 & 19.

Screw

Spade

Nut

Nut

(Handle) (Handle)

Kits*

Vacuum Switch Repair Kit

1 Reqd

1 Reqd

1 Reqd

1 Reqd

2 Reqd

2 Reqd

2 Reqd

1 Reqd

is p/n 10798. Kit contains

406M-04

7258

---

---

---

---

---

---

---

10956

items 14, 15, 29 & 34.

406M-04N26

7258

7044

7297

9850

9857

6831

5974

---

10956

406MK-04N26

7258

7044

7297

1

9850

9857

6831

5974

7047

10956

1

 Five Required.

Items 28 - 34 are not shown on illustration.

DIMENSIONS

EXPLODED VIEW & PARTS LIST

REV. 02/08

ww.oberdorfer-ppumps.com

PHONE  800-4448-11668;  (315)  437-00361

FAX  (315)  463-99561

Reviews: