9
Appendix
56 / 72
America
January 2017
9
APPENDIX
9.1
Decommissioning
Routine decommissioning
Routine decommissioning includes, for example,
decommissioning for maintenance work.
1
Lockout and Tagout.
2
Close the shutoff valves between the
compressor and the compressed air network.
3
Relieve the pressure in the aftercooler by
carefully opening the pressure relief valve.
Decommissioning for an extended period of
time.
For decommissioning for more than six months,
contact Gardner Denver.
Final decommissioning
In order to prevent renewed commissioning of the
compressor or misuse by unknown persons, the
compressor must be rendered unusable.
The compressor is made unusable by removing
the electronic controller. Consult Gardner Denver.
9.2
Consumables and auxiliary
materials
The compressor contains approximately
120 litres / 31.7 gal of oil.
There are two grease cartridges in the lubricator of
the drive motor.
Material safety data sheets
When handling consumables and auxiliary
materials, the associated material safety data
sheets must be adhered to.
Lubricating oil: AEON 9000SP
Lubricating grease: MOBIL POLYREX EM
9.3
Disassembly
WARNING
Damage to health
Risk of damage to health from
consumables and auxiliary materials
Consumables and auxiliary materials
can cause irreparable damage to health,
induce allergies, or irritate mucous
membranes.
➯
Follow the locally applicable
operating instructions and
hazardous material safety data
sheets when handling consumables
and auxiliary materials.
➯
Avoid direct contact with
consumables and auxiliary
materials. Wear personal protective
equipment.
➯
In case of injuries associated
with consumables and auxiliary
materials, consult a physician and
indicate the material involved.
Keep the safety data sheet for the
causative material available.
CAUTION
Slip hazard
Slip hazard due to spilled consumables
➯
Clean up escaped consumable
materials immediately.
➯
Avoid direct contact with
consumables. Wear personal
protective equipment.
Prerequisites
The compressor is shut down.
– The compressor is electrically disconnected.
– The main disconnect switch is switched to
OFF and secured against restarting.
– The compressor is not pressurized.
– Liquids and greases are removed to the
greatest extent possible.
Summary of Contents for L160 110A V2
Page 1: ...User manual Screw compressor L160 L290 V2 L160RS L290RS V2 America ZS1149274 03 January 2017...
Page 7: ...Foreword 1 January 2017 America 7 72 1 6 Rating plate Fig 1 1 Rating plate...
Page 69: ...Appendix 9 January 2017 America 69 72...