7
www.gd-elmorietschle.com
© Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH
|
Safety
2.3 Designated use
The machine must only be operated in such areas
as are described in the operating instructions:
• only operate the machine in a technically perfect
condition
• do not operate the machine when it is only par-
tially assembled
• the machine must only be operated at an ambi-
ent temperature and a suction temperature of
between 12 and 40°C
Please contact us for temperatures outside this
range.
• the machine may convey, compress or extract
the following media:
• Air
The air extracted may contain water vapour
but no water or other liquids. For water va-
pour compatibility see Info I 200
• all non-explosive, non-inflammable, non-ag-
gressive and non-poisonous dry gases and
gas air mixtures
2.4 Unacceptable operating modes
• extracting, conveying and compressing explo-
sive, inflammable, aggressive or poisonous me-
dia, e.g. dust as per ATEX zone 20-22, solvents
as well as gaseous oxygen and other oxidants
• extracting, conveying and compressing ex-
plosive, inflammable, aggressive, oxidative or
poisonous media, e.g. dust as per ATEX zone
20-22, solvents
• using the machine in non-commercial plants if
the necessary precautions and protective meas-
ures have not been taken in the plant
• installing in environments that are at risk of ex-
plosions
• using the machine in areas with ionising radia-
tion
• back pressures on the outlet side of more than
+0,1bars
• modifications to the machine and accessories