4.1.1  Data plate

Fig. 3  Data plate

4.2  Description

The C-VLR 301 model has a connection flange on the inlet side and an exhaust silencer on the pressure side 
(Fig. 2/B

1

). The air sucked in is cleaned by a micro-filter. An integral non-return valve prevents the evacuated 

system from being ventilated after the pump has stopped.
The ZEPHYR VLR 301 is a double shaft rotary piston vacuum pump in which the claws roll off against each 
other contact free and dry. The counter-rotating claw rotors are synchronised by a gear pair in the gearbox. 
The synchronous gearbox gear wheels and the bearings are lubricated with oil. These components are in 
a gearbox that also contains the oil supply. Oil conveying devices always ensure that the bearings and the 
gear wheels are sufficiently supplied with oil at all permissible speeds.
The gearbox and the compression chamber are separated from each other by special seals. The gearbox 
is sealed from the outside with shaft seals and O rings, the compressor chamber with piston rings. The 
VLR 301 is enclosed in an insulating hood. In order to dissipate compression heat, the cooling air is sucked 
through between the machine and the hood using a drum fan that sucks in the fresh cooling air (Fig. 2/E) 
and discharges the heated air out of the cooling air outlet (Fig. 2/F).
The VLR 301 is driven by standard flanged three-phase motors via a coupling.
A vacuum relief valve is incorporated into the machine.

4.3  Areas of application

This contact free running claw vacuum pump,  the C-VLR 301, can be operated constantly at any pressure 
between 700 mbars (abs.) and an inlet pressure of 150 mbars (abs.). 
When evacuating closed systems the volume to be evacuated must be no more than 2% of the nominal 
suction capacity of the vacuum pump.
The suction capacity with unrestricted suction is 290 m

3

/h at 50 Hz. Data sheet D 890 shows the depend-

ency of the suction capacity on the intake pressure.
Design “XD”:  The vacuum pump is provided with a corrosion-resistant coating and is suitable for conveying 

water-moist gases (water vapor). Special accessories are optionally available. 

  Please find further information in the supplementary sheet M 34.

If the unit is switched on more frequently (at regular intervals of about 10 times an hour) or at 
higher ambient temperatures and intake temperatures, the excess temperature limit of the motor 
winding and the bearings may be exceeded.Please contact the manufacturer should the unit be 
used under such conditions.
If it is installed in the open air the unit must be protected from environmental influences, (e.g. by 
a protective roof).

Type/ Size (mechanical version)

Serial number

Year of construction

Data matrix barcode

Item no.

Speed

Motor rating

Operating mode

Suction capacity

10 

Ultimate vacuum (abs.)

Following information are encrypted in the barcode:

•  Material number (MA)
•  Production order (PR)
•  Serial number (SC)

Summary of Contents for Elmo Rietschle C-VLR 301

Page 1: ...C Serie C Series Klaue Claw Edition 1 1 20 7 2017 BA 885 EN Original Operating Instructions C VLR 301 Vacuum pump...

Page 2: ...the operator 8 2 8 Safety instructions for installing commissioning and maintenance 9 2 9 Guarantee conditions 9 3 Transport storage and disposal 10 3 1 Transportation 10 3 1 1 Unpack and check the d...

Page 3: ...nd GmbH Table of contents 7 Maintenance and repair 20 7 1 Ensuring operational safety 20 7 2 Maintenance work 20 7 2 1 Changing the oil 21 7 2 2 Air filtering 22 7 2 3 Coupling 23 7 3 Repair Service 2...

Page 4: ...nying documents Document Contents No Supplier documentation Operating Instructions BA 885 Declaration of Conformity C 0080 Declaration of harmlessness 7 7025 003 17 Spare parts list Spare parts docume...

Page 5: ...create a vacuum Claw Machine s design or active principle Suction capacity Vacuum pump volume flow related to the condition in the suction con nection Final pressure abs The maximum vacuum that a pum...

Page 6: ...ions for installation commissioning maintenance and inspection work which must be obeyed to en sure the safe operation of the machine and prevent physical and material damage The safety instructions i...

Page 7: ...mable non ag gressive and non poisonous dry gases and gas air mixtures Version XD moist gases and gas air mixtures 2 4 Unacceptable operating modes extracting conveying and compressing explo sive infl...

Page 8: ...h electricity personnel being trained to work on the ma chine must be supervised by technical special ists only 2 6 Safety conscious work The following safety regulations apply in addition to the safe...

Page 9: ...ions Fit or start up safety and protective devices again immediately after finishing work Conversion work or modifications to the ma chine are only permissible with the manufactur er s consent Only us...

Page 10: ...the items being transported falling or tipping over Remember the centre of gravity when transport ing with a forklift truck or platform lift truck When transporting with the lifting device remem ber a...

Page 11: ...ge guidelines Page 4 3 3 Disposal WARNING Danger from inflammable corrosive or poiso nous substances Machines that come into contact with hazardous substances must be decontaminated before disposal Wh...

Page 12: ...p A Vacuum connection B Air outlet connection B1 Exhaust silencer B2 Condensate drain only with version XD D Suction flange E Cooling air inlet F Cooling air outlet H Oil filling point I Oil sight gla...

Page 13: ...the cooling air outlet Fig 2 F The VLR 301 is driven by standard flanged three phase motors via a coupling A vacuum relief valve is incorporated into the machine 4 3 Areas of application This contact...

Page 14: ...ling air coming out must not be sucked in again For mainte nance work there must be a minimum of 40 cm in front of the suction flange Fig 2 D 5 2 Installation NOTICE The machine may only be operated w...

Page 15: ...ipe is too narrow and or too long c The extracted air can be discharged through the exhaust silencer Fig 2 B or conducted away via a pipe NOTICE Exhaust air must not be restricted No blocking systems...

Page 16: ...ed in the motor s terminal box not for the plug connection version The motor data must be compared with the data of the existing mains network current type voltage network frequen cy permitted current...

Page 17: ...hen the machine is at operating temperature the surface temperatures on the components Fig 2 Q may go above 70 C You must avoid touching the hot surfaces mar ked with warning plates CAUTION Noise emis...

Page 18: ...ion of rotation leads to damage to the machine Use a phase sequence indicator to check the direc tion of rotation clockwise rotating field 6 1 2 Post run For removing accrued dampness and impurities o...

Page 19: ...sconnect the machine from the electricity source d Depressurise the machine Open the pipes slowly The pressure reduces slowly e Remove the pipes and hoses f Drain condensate from the silencer design X...

Page 20: ...s on the machine With any work observe the safety instructions described in Section 2 8 Safety notes for installation com missioning and maintenance The whole unit should always be kept in a clean con...

Page 21: ...lations If you are going to use another oil type empty the oil removing device housing and oil cooler completely A minimum oil quantity can get out of the vent screw duetopressurecompensation Iflarger...

Page 22: ...ned by rinsing out or purging or replaced more or less often de pending on how dirty the discharged medium is Remove the suction flange Fig 5 D after undoing the screws Fig 5 s1 Also check the valve s...

Page 23: ...not be switched on again Undo the screws Fig 7 s5 on the motor flange Re move the motor with the coupling half on the motor side Fig 7 q from the fanhousing Fig 7 n2 axi ally and suspend using a lifti...

Page 24: ...rs Please contact the manufacturer for the address of the service centre responsible for you see Manufac turer s address NOTICE For each machine that is sent to an Elmo Rietschle Service centre for in...

Page 25: ...duct Documents C Series Spare Parts Parts subject to wear and gaskets are indi cated separately on the list Web site http www service er de Select the type size and design NOTICE Only use original spa...

Page 26: ...ilter is dirty Clean or replace the filter Section 7 2 2 Section 7 4 The suction pipe is too long or too narrow Check the hose or the pipe Section 5 3 Machine or system leaking Check the pipework and...

Page 27: ...onnection flange G 2 Exhaust air outlet flange G 2 Condensate drain silencer Rp Correct amount of oil l 1 5 The length and the weight may differ from the information listed here depending on the motor...