background image

GB

S

NL

D

FI

N

GARDENA

®

C 1060 profi

Art. 1815 

GB

Operating Instructions 

Water Computer Profi 

S

Bruksanvisning

Bevattningscomputer 

NL

Gebruiksaanwijzing 

Besproeiingscomputer 

D

Gebrauchsanweisung 

Bewässerungscomputer 

FIN

Käyttöohjeet

Kasteluohjain  

Summary of Contents for C 1060 Profi

Page 1: ... profi Art 1815 GB Operating Instructions Water Computer Profi S Bruksanvisning Bevattningscomputer NL Gebruiksaanwijzing Besproeiingscomputer D Gebrauchsanweisung Bewässerungscomputer FIN Käyttöohjeet Kasteluohjain ...

Page 2: ...otes on safety For safety reasons children and young people under 16 as well as anyone who is not familiar with these operating instructions must not use the Water Computer v Please keep these operating instructions in a safe place 1 Where to Use Your GARDENA Water Computer 3 2 For Your Safety 3 3 Function 5 4 Putting Your Water Computer into Operation 8 5 Programming 11 6 Automatic Water Distribu...

Page 3: ... intended for pri vate use in domestic and hobby gardens exclusively for outdoor use to control sprinklers and watering systems The GARDENA Water Computer must not be used for indus trial purposes or in conjunction with chemicals foodstuffs easily flammable and explosive materials 2 For Your Safety Battery To ensure the Water Timer runs safely only a 9V alkaline manganese battery alkaline type IEC...

Page 4: ...functions correctly is 20 30 l h For example at least 10 x 2 litre Drip Heads are required to control the Micro Drip System At high temperatures over 60 C at the dis play the LCD display may extinguish This does not affect the program in any way When the computer cools down the LCD display illuminates again The max temperature for the water flow is 40 C v Only use clear fresh water The minimum ope...

Page 5: ... choose You can use your Water Computer to water your garden early in the morning or late at night when water evaporates the least or when you are on holiday You simply program the watering start watering time and watering day s or cycles Key Key operated function 1 Changes or moves on the input data If the key is held down the figures change very quickly 2 O K Confirms the values set with the key...

Page 6: ...de for watering start time 0 P PM M Display for 12 h clock e g in USA Canada A Time Current time Watering start time Start time display 13 h 1 pm e g in USA Canada B R RU UN N T Tiim me e Watering time flashes when in input mode C 3rd 2nd Watering cycles 3rd every 3rd day 2nd every 2nd day D Run Budget function the watering time of all watering Time programs can be reduced centrally in intervals o...

Page 7: ...ry with a new one G Prog Watering program inactive Off Budget function 0 The four display levels Level 1 Normal display Level 2 Enter the current time and day of the week Level 3 Insert watering programs Level 4 Run Time Prog Off can be selected one after the other by pressing the Menu key You can change display level at any time even during program ming All the program data which have been confir...

Page 8: ... Water Computer housing 2 Insert battery J into battery compartment Ensure that the battery polarity is correct The display shows all the LCD symbols for 2 seconds and then moves to the time day of week level 3 Re insert control unit I in housing Programming aid v Stick the self adhesive programming aid on the inside of the display cover The display cover can be folded up to protect the display ag...

Page 9: ...2 Screw tap connector M on to the Water Computer Connect Water Computer to tap with G 3 4 26 5 mm thread 1 Screw adaptor K on to the tap manually do not use pliers 2 Screw sleeve nut L of the Water Computer on to the adaptor thread K by hand do not use pliers 3 Screw tap connector M on to the Water Computer Before you start entering the watering data in the computer we recommend that you write the...

Page 10: ...Off is unaffected by this 1 Place soil moisture sensor in the watered area or place rain sensor with extension cable if necessary outside the watered area 2 Insert the sensor in the sensor connection N of the Water Computer Connect soil moisture or rain sensor optional Program Starting time Watering time Watering days Watering cycles PROG START TIME RUN TIME Mo Tu We Th Fr Sa So 2nd 3rd 1 7 30 0 3...

Page 11: ... remove the screw after it has been screwed in 5 Programming The control unit I can be removed from the housing for pro gramming by pressing the unlock button H and programming can be undertaken whilst you are moving around see 4 Putting Your Water Computer into Operation Insert battery 1 Press Menu key not necessary if the battery has just been inserted The hours display and t tiim me e flash Fit...

Page 12: ...h 4 Set the day of the week with the key example Sa Saturday and confirm with the O K key The display moves to the message Insert watering programs and program memory setting 1 flashes You must reset your Water Computer before selecting the special function see 6 Automatic Water Distributor v Reset Keep key and O K key pressed simultaneous for 2 seconds Up to 6 watering programs can be inserted or...

Page 13: ... memory setting 1 is selected automatically s st ta ar rt t t tiim me e and the hours section flash on the display 3 Select program memory setting with the key example Prog 3 program 3 and confirm with the O K key s st ta ar rt t t tiim me e and the hours section flash on the display 4 Set the hours for starting the watering time with the key example 6 6 hours and confirm with the O K key s st ta ...

Page 14: ...ours and confirm with the O K key R RU UN N T TIIM ME E and minutes for the watering time flash on the display 7 Set watering time minutes with the key example 1 10 0 minutes and confirm with the O K key Watering cycle 3rd flashes on the display 8 a Select watering cycle with the key example 2nd and confirm with the O K key 2nd 3rd watering every 2nd day 3rd day The display returns to step 3 and t...

Page 15: ...age Run Time Prog Off You must select the Run Time percentage you wish to activate before the watering programs can run 9 Press Menu key 3 times not necessary if the program has just been compiled for program memory setting 6 10 Select the percentage see Budget Function for the pro grammed watering time using the key e g 6 60 0 Run Time and then confirm your selection by pressing the O K key The d...

Page 16: ... set on one of the 6 program memory settings this can be modified without having to compile it from the beginning again 1 Press Menu key twice Program memory setting 1 flashes 2 Press O K key to move to the next program step or modify program data with the key and confirm with the O K key The valve can be opened or closed manually at any time A program controlled open valve can also be closed earl...

Page 17: ... is closed The amended manual opening period is stored i e each time the valve is opened manually in future the modified opening period is preset If the manual opening period is amended to 0 0 0 00 0 the valve is closed and also remains closed after the man On Off key is pressed child lock If the valve has been opened manually and a programmed start of a watering period overlaps the manual opening...

Page 18: ...k are retained If no entry is made during programming for a period of more than 60 seconds the normal display reappears With overlapping programs and identical watering days the 1st watering starting time has priority and other programs are not initiated Example The first program is run on Monday the 2nd program is cancelled Program Starting time Watering time Watering days Watering cycles PROG ST...

Page 19: ... Computer C 1060 profi is able to take into account the special requirements of the Automatic Water Distributor when programming If program data have already been inserted beforehand a RESET must be undertaken before the special function can be set v Keep key and O K key pressed simultaneously for 2 seconds To ensure the Automatic Water Distributor switches safely there must be at least a 30 minut...

Page 20: ...not take into account the break times mentioned above any changes you make are not accepted and an error message appears on the display E ER RR RO OR R Since it is very easy for watering times to overlap slightly espe cially when the beginnings and ends of programs are very close together it is sensible to RESET the Water Computer and to re enter the watering data to prevent an error message appea...

Page 21: ... special function is activated and the Soil Moisture or Rain Sensor indicates sufficient moisture watering is interrupted The watering time of following watering programs is shortened to 30 seconds display 1 1 min until the Soil Moisture Rain Sensor allows the watering programs to be resumed The water ing time originally entered then begins Shortening the watering time when the soil is sufficientl...

Page 22: ...Remove filter from sleeve nut L and clean 3 Screw sleeve nut L of the Water Computer back on to the thread of the tap by hand do not use pliers Clean filter L 8 Trouble Shooting Fault Possible Cause Remedy No display appears Battery inserted incorrectly v Check polarity markings match Flat battery v Insert new alkaline battery v Check function by operating manually man On Off ...

Page 23: ...tt v Insert new alkaline battery man On Off key is not indicator flashes possible Manual watering period is set v Set manual watering period to 0 0 0 00 0 to a figure greater than 0 0 0 00 0 see 5 Programming Tap turned off v Turn tap on Watering program is not Watering program has not v Read off watering program being undertaken been entered completely and modify if necessary no watering Programs...

Page 24: ...rt time has program without overlaps priority Soil moisture or rain sensor v If dry check setting reports sufficient moisture location of soil moisture rain sensor Batt indicator flashes because v Insert new alkaline battery battery is almost flat Water Computer does Minimum quantity of water v Connect more drip heads not close drawn is less than 20 l h If you have any other problems with your Wat...

Page 25: ...r in a dry place where it is protected from frost Please return flat batteries to a GARDENA dealer or dispose of them properly at your nearest recycling centre Only dispose of batteries when they are flat 10 Accessories Automatic control with GARDENA Soil Moisture Sensor Art No 1187 GARDENA Rain Sensor electronic Art No 1189 GARDENA Automatic Water Distributor Art No 1198 Over wintering storage ...

Page 26: ... Clear fresh water Max medium temperature 40 C Number of program controlled watering cycles per day Up to 6 Watering duration per program 1 min to 9 hours 59 min Battery required 1 9V alkaline manganese alkaline battery type IEC 6LR61 Operating time of the battery approx 1 year ...

Page 27: ...ith the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit Damage caused by frost is not covered by the warranty This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If you have any problems with your Water Computer please contact our Customer Service or return the...

Reviews: