RTxxx LED lighting controllers - User Manual
Where:
c
= output channel (1 to 2, 4 or 8, depending on model)
p
= trigger input (1 or 2)
This command can be used to override the state of an input. The
override is cancelled as soon as an edge is detected on the input.
12.3.3 Command summary
Command
Example
Effect
AW
AW
Save changes.
CL
CL
Clear configuration.
GT
GT1
Enable Ethernet messages.
GR
GR
Clear any error conditions
EY
EY65,66
Set webpage password to 'AB'.
VR
VR
Read the firmware version.
VL
VL1,0,0.5
Set the rating of channel 1 to 0.5A.
RS
RS2,65
Set channel 2 to 65% brightness
continuous.
RW
RW1,50
Set channel 1 to 50% switch mode.
RU
RU1,75,25
Set channel 1 to selected mode at
75% and 25%.
RT
RT2,3,4,50
Set channel 2 to 3ms pulses, delayed
by 4ms at 50% brightness.
RP
RP1,2
Output channel 1 is triggered using
output 2
RE
RE1,3
Set channel 1 to ignore lighting errors
and not prompt for the current rating of
a light when it is connected.
TT
TT1,1ms
Set internal triggers every 1ms.
TR
TR2
Trigger channel 2.
ST
ST2
Show configuration for channel 2.
—
61
—
RTxxx LED lighting controllers - User Manual
Set selected mode
The output is set to selected mode with two brightness settings.
RUc,s,t
Where:
c
= output channel (1 to 2, 4 or 8, depending on model)
s
= brightness 1 setting in percent (s = 0 to 100)
t
= brightness 2 setting in percent (t = 0 to s)
Set pulse mode
The output can be set up to pulse on a trigger input. The delay from
trigger to the start of the pulse, the length of the pulse and the
brightness are configurable.
An error is generated if the brightness setting requires a current
greater than 20A or if the combination of pulse width and setting is
not allowed.
RTc,p,d,s
RTc,p,d,s,r
Where:
c
= output channel (1 to 2, 4 or 8, depending on model)
p
= pulse width in milliseconds (0.02 to 999)
d
= delay from trigger to pulse in milliseconds (0.02 to 999)
s
= setting in percent (s = 0 to 999)
r
= retrigger delay. This parameter is optional.
Set the Option Flags
REc,m
Where:
c
= output channel (1 to 2, 4 or 8, depending on model)
m
= flags:
bit 1 =
0
1
E flag set (error detection enabled)
E flag cleared (error detection disabled)
bit 2 =
0
1
P flag set (positive triggers)
P flag cleared (negative triggers)
Set the Trigger Input
This command sets which input is used for pulse and switch output
modes.
RPc,p
—
60
—