RC1xx - User Manual
RC100
RC120
Operating
temperature
5° to 50°C
Humidity
Up to 95% (non-condensing)
11.2
Restrictions
The following timings and restrictions are applied when commands are
entered. Exceeding these values causes an error to be returned.
The keypad interface prevents invalid values being entered at the
controller.
11.2.1 Continuous mode
The maximum continuous output current is 1A for the RC100 and 1.2A for
the RC120.
11.2.2 Switched mode
The maximum delay from the trigger input changing state to the output
current switching on or off is 100µs.
The maximum output current is 1A for the RC100 and 2A for the RC120.
11.2.3
Pulse mode
The maximum pulsed output current is 1A for the RC100 and 2A for the
RC120.
When you set a delay of 0µs, there is a delay of approximately 4µs.
For pulse widths of 100µs the output voltage and current cannot be
measured. Because of this, fault detection is disabled and thefollowing
conditions apply:
For pulse currents greater than 0.5A, the duty cycle is restricted to 1%.
For pulse currents less than or equal to 0.5A , the duty cycle is restricted
to 10%.
Pulse
output
current
TR-RC120
TR-RC122
≤
1A
100ms max pulse width
100ms max pulse width
> 1A
10ms max pulse width
10ms max pulse width
> 1.5A
50% max duty cycle
50% max duty cycle
> 2A
Not applicable
1ms max pulse width
50% max duty cycle
> 3A
Not applicable
1ms max pulse width
10% max duty cycle
> 5A
Not applicable
1ms max pulse width
7% max duty cycle
—
39
—