RC1xx LED Lighting Controllers - User Manual
—
20
—
For example, for RC12x serial number 12345, IP address 192.168.1.103,
MAC address 00.0B.75.01.80.99 the packet comprises:
Gardasoft,RC12x,012345,000B75018099,C0A80167
9
Web page configuration (RC120)
You can set up the RC120 through its own internal web pages. After
locating your controller on your network, click the
Open webpage...
button
in GardasoftMaint to take you directly to the RC120’s web pages. You can
also type the controller’s IP address (displayed in GardasoftMaint) into your
web browser, which will display the Main page. GardasoftMaint software is
available from
9.1
Main page
The main page (shown below) is the first to open when you access the
RC120’s web pages. This gives the controller’s hardware and firmware
revision levels and the serial number. It also tells you the power being
dissipated and the RC120’s internal temperature.
9.2
Configuration page
The configuration page allows you to set up the lighting parameters,
view the light data, and view the measurements the RC120 makes
during operation. To refresh this page it is important that you click the
Refresh
button on the web page (
) rather than on your web browser.
When configuration changes are submitted, the URL includes the new
configuration, so refreshing the page re-submits the URL.
You can set the mode (continuous, pulsed, or switched), the light’s
brightness and pulse settings. You must click the
Submit
button to effect
any changes you make.
Click the
Refresh
button at the bottom of the screen to update the
measurements being taken.