OC-G-5646-2-ET OLED Lighting Controllers - User Manual
11.4
Fatal error codes
Error number
Reason
Er r 44
The inter nal tem per atur e of the OC-G-5646-2-ET
has becom e too high.
Er r 40, Er r 41
Er r 45
One channel is outputting m or e cur r ent than
expected.
Er r 47
Inter nal pr otection has pr evented too m uch heat
in the output dr iver .
11.5
Event codes
Event m essages ar e sent when a light is connected or an er r or occur s.
The for m at of these is:
Evt<channel>,<event code>;
These event m essages ar e only sent after the
GT1
com m and has been
sent.
Event
number
Reason
1 to 127
An er r or has occur r ed. The er r or code is given by
the event num ber .
128
A light has been connected and is wor king.
130
An over tem per atur e er r or occur r ed.
131
An over cur r ent er r or occur r ed.
138
SafePower tr ainup has com pleted.
139
SafePower tr ainup has failed or been cancelled.
144
OLED connected.
145
OLED connection er r or .
146
OLED disconnected.
147
OLED lifetim e war ning.
148
OLED lifetim e over .
149
Er r or saving OLED infor m ation.
—