TR-RC1xx - User Manual
dEL
is displayed. Press the
SEL
button
to set up the pulse delay time. Refer to
Setting time periods. Press the
SEL
button.
PUL
is displayed. Press the
SEL
button
to set up the pulse width. Refer to
Setting time periods. Press the
SEL
button.
rEt
is displayed. Press the
SEL
button
to set up the retrigger time. Refer to
Setting time periods. Press the
SEL
button.
Use the
p
and
q
buttons to set the
Trigger flag:
F P
is enabled,
F-P
is
disabled. Press the
SEL
button.
Use the
p
and
q
buttons to set the
Error Detect flag:
F E
is enabled,
F-E
is
disabled. Press the
SEL
button.
Pulsed operation is set up.
Note:
If you set the brightness to more than 100%, the pulse width is
limited to a safe value as described in
Section 7.1, Pulse and duty cycle
.
10.2.6 Setting time periods
When the TR-RC requires you to enter a numeric value, the right hand digit
flashes to indicate you can use the
p
and
q
keys to change the value.
To set pulse delay, retrigger and pulse width values a scheme is used
where the exponent (power of ten) of the value is set. The exponent values
are as follows:
Exponent
value
Number
format
Range of values
E-2
9.99
Values are displayed in seconds from
10ms to 5 seconds in steps of 10ms.
E-3
999.
Values are displayed in milliseconds from
1ms to 999ms in steps of 1ms.
E-4
99.9
Values are displayed in milliseconds from
0.1ms to 99.9ms in steps of 0.1ms.
Follow the keystrokes overleaf to enter numerical data into the
TR-RC using the above scheme.
—
26
—