N m
in lb
ft lb
The desired torque unit is defined here.
Target torque (STOP) M
The target torque value is defined here.
No tolerance specification
Relative tolerance specification
Absolute tolerance specification
Whether a tolerance range is assigned to the value is defined
here. The tolerances may be specified relative to the value as
a percentage. An absolute tolerance specification with
concrete values is also possible.
Upper torque tolerance limit UT (M
UT
)
Lower torque tolerance limit LT (M
LT
)
The torque tolerance range is defined here.
If no tolerance specification has been selected, this menu item
is not displayed.
Peak (P)
Track (T)
The function mode is selected here. See page 14.
Extension length
The extension length for the installed plug-in tool is input here.
Summarisation
A summarisation of the settings which have been made is
displayed here. The summarisation can be confirmed with OK
or the bolting process may be commenced. The
summarisation is automatically hidden.