3/4
CHECKING/CHANGING DIRECTION
IMPORTANT: change direction must be performed before starting limit
setting otherwise limits must be reset.
Press UP or DOWN the motor should go UP or DOWN, otherwise to change
direction:
1
Press and hold the PROG-TX
button until the motor starts
moving
2
Press STOP: The motor makes a
brief jog. Direction of the motor
has been reversed.
PROGRAMMING
ERASING TRANSMITTER
Push simultaneously the PROG-TX
button and STOP of the transmitter until
the motor makes a brief movement in
both directions.
Only the transmitter used for this
procedure has been deleted from motor
memory.