background image

3/4

CHECKING/CHANGING DIRECTION

IMPORTANT: change direction must be performed before starting limit 

setting otherwise limits must be reset.

Press UP or DOWN the motor should go UP or DOWN, otherwise to change 

direction:

1

Press and hold the PROG-TX 

button until the motor starts 

moving

2

Press STOP: The motor makes a 

brief jog. Direction of the motor 

has been reversed.

PROGRAMMING

ERASING TRANSMITTER

Push simultaneously the PROG-TX 

button and STOP of the transmitter until 

the motor makes a brief movement in 

both directions.

Only the transmitter used for this 

procedure has been deleted from motor 

memory.

Summary of Contents for XQ50

Page 1: ...Made in Italy MX Tubular motors with mechanical limit switch manual override and integrated receiver ...

Page 2: ...INDEX SAFETY INSTALLATION ELECTRICAL CONNECTION ERASING TRANSMITTER PROGRAMMING TRANSMITTER RESET MOTOR MEMORY ADDING TRANSMITTER LIMIT SWITCH SETUP CHECKING CHANGING DIRECTION MANUAL OVERRIDE ...

Page 3: ...istance of at least 0 4 m from it completely open and whatever fixed item in the nearby The device is not intended to be used by people including children whose physical sensory or mental capabilities are reduced or lacking experience or knowledge unless they have been granted through the intermediary of a person responsible for their safety supervision or instruction concerning the use of the dev...

Page 4: ...atalogue WARNING incorrect installation can cause serious injuries Follow the installation instructions Before you remove all unnecessary cables and turn off any equipment not required for this operation 1 Fix the adaptors to the motor distinguishing the limits ring from the drive pulley A B 2 Insert the motor into the tube until its end stops against the limits ring E F INSTALLATION ...

Page 5: ...ert it into the tube F 90 min 1 8 m C D NOTES For the XQ50 with torque up to 15Nm the minimum tube diameter is 50x1 5mm for motors with higher torques the minimum tube diameter is 60x1 5mm For the XQ60 the minimum tube diameter is 63x1 5mm WARNING The screws used to fix the last slat on the tube may be too long and reach the tubular part of the motor Use appropriate screws or fixing clips Motor mo...

Page 6: ...ce between contacts of at least 3mm The motors connecting cables to the network can only be replaced with cables of the same type provided by the motor manufacturer Do not connect more than one tubular motor to a single switch Do not set the shutter awning into motion while you are cleaning or servicing the device and disconnect the supply The switch controlling the motor must be installed in full...

Page 7: ...ith others 1 Power up the motor to be programmed OFF ON 2 Press and hold the PROG TX button until the motor starts moving 3 Check the rotation of the motor then release PROG TX the motor stops 4 Within 5 seconds press the corresponding button i e UP if the motor rotates upwards or DOWN if vice versa The transmitter has been programmed and the rotation of the motor has been synchronized PROGRAMMING...

Page 8: ... the rotation of the motor then release the PROG TX button the motor stops 3 Within 5 seconds press the cor responding button i e UP if the motor rotates upwards or DOWN if vice versa on the new tran smitterbeingadded The new transmitter has been programmed and the rotation of the motor has been synchronized PROGRAMMING ...

Page 9: ...change direction 1 Press and hold the PROG TX button until the motor starts moving 2 Press STOP The motor makes a brief jog Direction of the motor has been reversed PROGRAMMING ERASINGTRANSMITTER Push simultaneously the PROG TX button and STOP of the transmitter until the motor makes a brief movement in both directions Only the transmitter used for this procedure has been deleted from motor memory...

Page 10: ... a brief jog and after a while a second long jog Memory is now empty x2 OPTION2 Withoutanalreadyprogrammedtransmitter 1 Switch the motor power supply OFF Then switch it ON OFF ON ON 2 Within 8 seconds using any Gaposa transmitter press and hold both the PROG TX and STOP buttons until the motor makes a long jog Memory is now empty PROGRAMMING ...

Page 11: ... for shutters installed in internal boxes and for awnings with rear motor winding In case shutters are in an external box or awnings wind front motor the setting screws must be read reversed ex up as down and vice versa NOTES Arrows indicate the direction of rotation controlled by each adjusting screw Arrows indicate the screw direction for increasing or decreasing revolutions controlled by the li...

Page 12: ...g the shutter awning at the tube and then turn the lower adjusting screw to or in order to set the exact desired down position 4 Open the shutter roll up the awning until it does not stop and then turn the upper screw to till the shutter awning reaches the exact desired up position In case you need to correct the up limit position because it s over close the shutter roll the awning down shortly th...

Page 13: ...anual override in some installation examples IMPORTANT The motor with manual override must be installed orthogonal to the fixing plate and in a roller tube perfectly horizontal The manual override device on the head of the motor cardan joint with eye or shaft with eye must be fixed not higher than 1 8m ...