108
GAP Diagnostic 2019-07-15 All Rights Reserved
User Manual : Version 33, Firmware V3.0
Option 1 : Calibrating the left sensor and using the right side as reference.
6. The correct calibration is achieved by adjusting only the left side of the vehicle to match the
right. Calculate the new calibration value for the left side using the formula below. To do the
calculation, fill in the table below or on the
EAS Calibration Aid
with the values noted for front
corners and repeat for rear corners.
All values are in millimetres
Front
Current Calibration Values
Current Height Values
Measured Heights
Front Left
X=
A=
C=
Front Right
B=
D=
Table 29.
Required data, front left calibration
Rear
Rear Left
X=
A=
C=
Rear Right
B=
D=
Table 30.
Required data, rear left calibration
Calibration Formula for left-hand adjustment
All values are in millimetres
New Calibration
Value Front Left
=
Old Calibration
Value Left X
+
Current
Height A
-
Current
Height B
-
Measured
height C
+
Measured
height D
=
+
-
-
+
New Calibration
Value Rear Left
=
Old Calibration
Value Left X
+
Current
Height A
-
Current
Height B
-
Measured
height C
+
Measured
height D
=
+
-
-
+
Table 31.
Calculus, new left side calibration value
*Please remember: when a value minus a negative value, the minus in the equation becomes a plus
(subtracting a negative number = adding a positive number). For example, 3 - -3 = 6