![Gap Diagnostic IIDTool Pro G3 User Manual Download Page 98](http://html2.mh-extra.com/html/gap-diagnostic/iidtool-pro-g3/iidtool-pro-g3_user-manual_5057204098.webp)
98
GAP Diagnostic 2023-09-12 All Rights Reserved
User Manual G3 units: Version 37, Firmware V4.0
Steps:
Figure 53.
Guided Calibration steps
•
The first corner to be calibrated is the front left corner (1).
•
Place your measuring tape as instructed and use the up and down arrows (2) to reach the requi
-
red height (3).
•
Once completed, click on Send (4). The next corner to be calibrated will now be highlighted.
•
Repeat the previous steps for all corners.
Notes:
• It is normal for the opposite corner to move when adjusting the height of a corner. This does not
affect in any way negatively the calibration.
• It is normal for the vehicle to be crooked during calibration. Once the process is completed, the
suspension will adjust the vehicle accordingly.
• Using a fabric tape measure taped to the center of the wheel will allow operation of the App
while measuring and ensure more consistent measures.
• Depending on the vehicle and axle, it is easier to control either the up or down motion. Use the
less precise as the starting point then adjusts more precisely.
• Marking the center of the wheel does help with consistent measures
.
•
Calibration of all corners is done in one iteration. Once a corner is calibrated, its calibration will
no longer be affected by movements induced by other corners being calibrated.