4.8.2 Viewing live values
Live value selection and sampling rate
You can select up to 8 live values in the graph and numeric display modes. All 8 values can be viewed
simultaneously. The maximum sampling rate of each live value is divided by the number of live values
selected. For example, if one live value is selected, the maximum sampling rate will be 16 per second
/ 1 live values = 16 samples per second. If four values are selected, 16/4 = 4 samples per second for
each live values. The absolute maximum sampling rate of each live value is determined by the ECU.
All except L322 2002 to 2004.
User can choose between tested and untested live values. Untested
live values will not work (N/A) on every vehicle and configurations. They may also be dependent on the
firmware version of the ECU.
Basic controls
Press in the yellow area to make the top option bar appear.
Figure 61.
LV :
Calling the top bar
Figure 62.
LV : Top bar options
Full screen / split screen button
This button begins recording data. Once pres-
sed, the stop button (same location) will allow the
user to stop, save and name the recording (log) if
required. Saved logs can be accessed by selec
-
ting “Logs” in the Live Values or login screen (off-
line mode allowed). See