DIP Switch Configuration
Unlike the Q.bloxx modules where the address of the measurement modules are
typically configured via software, the Q.brixx systems that are shipped from the factory
have the address configured via the DIP switches. These DIP switches are located on
the base of the module. Not only is the node address set using the switches, but
terminating resistors and UART settings are also set using this method.
1.
There are two versions of the Q.brixx base. Both versions work together on the
same system. The difference between the versions is the location of the DIP
switches.
2.
“Older” version has 1 x 10-pin dip switch and 1 x 4-pin dip switch.
3.
The 10-pin switch is used to set the address and/or terminating resistances.
PINs 1-6: Sets the address of the module (binary)