GL7p - Battery-powered, door-mounted electronic locker lock GL7p 
Operation

 

 

56 

HB_GL7p--EN_12 

www.gantner.com

 

6.3.4 

Personal Locker Programming Card Mode 

 
For lockers operating in “personal locker programming card” mode, up to 32 data carriers and/or 32 PIN codes per 
GL7p can be authorized for use. These 32 data carriers and/or 32 PIN codes can be used with the locker as often 

as required and share the same authorization access, e.g., for use as family cards.  

The data carriers are authorized for use with the personal locker using the PROGRAM data carrier (included in the 
GAT ECO.Basic Set, see section “6.4 GAT ECO.Basic Set FD”). 
 

Authorizing data carriers 
►  Close the locker door. 
►  Press the button of the GL7p in using the PROGRAM data carrier for approximately 1 second. 

o

 

The information on the data carrier is read and the LED flashes green briefly.  

► The GL7p enters into programming mode.  

o

 

The LED flashes red until the PROGRAM data carrier is removed. As soon as the PROGRAM data 
carrier has been removed, the LED flashes red/green and the lock is ready to program data carriers. 

►  Within 5 seconds, hold the data carrier being authorized in front of the GL7p button (the button does not need 

to be pressed). 

a) Successful authorization: The LED flashes green for approximately 3 seconds. When the data carrier is 

removed, the LED flashes red/green alternately again and another data carrier can be authorized in the 
same way. Repeat this process until all the data carriers are authorized.  

 

b) Unsuccessful authorization: The LED flashes red and the GL7p switches off. Possible reasons for this 

include: 

- The maximum of 32 data carriers are already authorized in the GL7p.  

- The data carrier could not be read correctly, e.g., because the data carrier is damaged. 

►  You can repeat the last step using different data carriers to program these data carriers successively. To do 

this, each data carrier being authorized must be held in front of the GL7p button within 5 seconds after 
removing the previous data carrier. If you wait longer than 5 seconds, the reading process is terminated, and 
the read data carriers are saved in the lock. 

 

Authorizing PIN codes 
►  Close the locker door. 
►  Press the button of the GL7p in using the PROGRAM data carrier for approximately 1 second. 

o

 

The information on the data carrier is read and the LED flashes green briefly.  

► The GL7p enters into programming mode.  

o

 

The LED flashes red until the PROGRAM data carrier is removed. As soon as the PROGRAM data 
carrier has been removed, the LED flashes red/green and the lock is ready to program data carriers. 

►  Within 5 seconds, enter the PIN code being authorized and confirm with the OK key (

) or by pressing the push 

button. 

a) Successful authorization: The LED flashes green for approximately 3 seconds. When the data carrier is 

removed, the LED flashes red/green alternately again and another PIN code can be authorized in the same 
way. Repeat this process until all the PIN codes are authorized.  

 

b) Unsuccessful authorization: The LED flashes red 3 times and the GL7p switches off. Possible reasons for 

this include: 

- The maximum of 32 PIN codes are already authorized in the GL7p.  

- The PIN code was not correctly entered, e.g., the PIN code was too short or too long or an invalid PIN code 

was entered.  

Summary of Contents for GL7p

Page 1: ...com HB_GL7p EN_12 1 GL7p Battery Powered Door Mounted Electronic Locker Lock Identification via RFID MIFARE ISO 15693 NFC HID iCLASS and Optional PIN Code Installation Configuration Operation Document...

Page 2: ...xclusively on the conditions of the guarantee Any further reaching claims are excluded and in particular the manufacturer accepts no liability for the completeness or accuracy of the contents of this...

Page 3: ...bols intended to inform the user about potentially hazardous situations or important information for the safe and proper use of the described product s The safety messages also include directives on h...

Page 4: ...he Signal Words Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates information considered important but not hazard related e g messages relating to pr...

Page 5: ...ance of the product must be carried out in accordance with the technical conditions of operation as described in the corresponding documentation Therefore it is essential to read the corresponding cha...

Page 6: ...ision reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the...

Page 7: ...brouillage 2 l appareil doit accepter tout brouillage radio lectrique subi m me si le brouillage est susceptible d en compromettre le fonctionnement ICES Statement Canada This Class B digital apparatu...

Page 8: ...GL7p Battery powered door mounted electronic locker lock GL7p 8 HB_GL7p EN_12 www gantner com...

Page 9: ...Installation 21 3 3 Replacement after a Burglary Attempt 21 3 4 Operating Conditions 21 3 5 Door Width and Thickness 22 3 6 Latch Types 22 3 7 Definition of the Door Hinge Right of Left Hinged Door 2...

Page 10: ...Unique Number Mode 55 6 3 4 Personal Locker Programming Card Mode 56 6 3 5 Personal Locker Expiry Date Mode 57 6 4 GAT ECO Basic Set FD 59 6 5 Summary of System Data Carriers 59 6 5 1 MASTER Data Car...

Page 11: ...GENERAL INFORMATION a functional description of the GL7p the RFID technologies supported by the device key terms used in this manual and a summary of system components can be found Chapter 3 INSTALLAT...

Page 12: ...property equipment 1 5 Formatting 1 5 1 Safety Critical Information The following formatting with example text is used in this manual to display important safety critical information that must be read...

Page 13: ...compatible with standard locker locks Suitable for left and right hinged doors low door heights and various locker materials Optional wireless interface for identification via smartphone Emergency po...

Page 14: ...ocks Depending on the variant of the lock used one or more of these options can be used Variant RFID 1 Wireless 2 PIN Code 3 Mounting method 4 GL7p 0500 X vertical top horizontal right horizontal left...

Page 15: ...fferent RFID technologies data carriers are available in a variety of shapes and sizes The GL7p is designed to operate with all different types of data carrier media 2 4 2 Lock Orientation For the GL7...

Page 16: ...nd in MIFARE systems the site key is used which is a combination of the FID and the read and write keys The FID and site key are unique for every facility These numbers are encoded in every data carri...

Page 17: ...rts A description of the individual components is provided on the following page Figure 2 1 Components of the GL7p locker system 3 GL7p 1501 4 GL7p 3501 7 GL7p 1502 7 GL7p 3502 1 GL7p 0500 5 GL7p 2500...

Page 18: ...eless interface with PIN keypad mounting on left hinged door without battery 9 GL7p Battery CoverKey Part No 749230 Tool for opening the battery compartment 10 GAT ECO Basic Set FD Part No 1100550 Set...

Page 19: ...ts of 50 stickers with pre printed numbers in the following number ranges GL7p Number Sticker 001 050 Part No 1103040 GL7p Number Sticker 051 100 Part No 1103041 GL7p Number Sticker 101 150 Part No 11...

Page 20: ...ns and Components 1 LED status indicator 7 Fixing nut 2 Button a unlocked b locked 8 Spacer sleeve 3 Latch 4 Front part 5 Rear part 6 Mounting thread M19x1 9 Screw for anti rotation protection 10 Batt...

Page 21: ...stallation applications always perform a test installation including functional testing of the GL7p in a sample locker from the facility before starting with the mass production of lockers Ensure that...

Page 22: ...When installing the GL7p in lockers with narrow doors ensure that the GL7p does not touch the locker body when opening and closing the door see following picture Figure 3 1 Width and thickness of the...

Page 23: ...latch follow these steps Install the supplied standard latch Lock the GL7p using a valid data carrier or PIN code while keeping the locker door closed so far that the latch retracts exactly into the...

Page 24: ...installation it is important to determine whether the locked door is hinged on the left or right side which is defined as follows Right hinged door Left hinged door Figure 3 5 Locker door hinge defini...

Page 25: ...left hinged doors You can make this change yourself see 3 8 2 Instructions for Installing the GL7p The installation for right hinged doors is described in the following pages The installation process...

Page 26: ...e Door Two holes must be drilled in the door If a DD cut out with 19 1 x 16 1 mm 0 75 x 0 63 in already exists e g when replacing an existing mechanical lock this can also be used Vertical mounting Ho...

Page 27: ...etal door 11 Washer only if spacer is not used 12 Screw for anti rotation 1 1 For doors with a thickness of 1 to 5 mm and 13 to 18 mm a corresponding KA35 screw is included with the delivery For other...

Page 28: ...pplied screw spacer sleeve For door thicknesses 5 to 10 mm KA35x20 screw spacer sleeve For door thicknesses greater than 10 mm supplied washer KA35 screw suitable for the door thickness or 3 5 mm tapp...

Page 29: ...t number GL7p Number Plate Part No 1103180 In addition a button sticker GL7p Number Sticker can be attached to the number plate however this is not mandatory The button sticker is available with pre p...

Page 30: ...ure that the surface of the button is free of dirt and dust Align the number plate with the 4 tabs in the button and attach it If applicable align the button sticker with the 4 tabs in the button and...

Page 31: ...battery becomes too weak the locker can no longer be locked The GL7p indicates a low battery condition by blinking the LED 5 times red during an unlocking and a locking attempt and the lock emitting...

Page 32: ...or unlocking attempt In this state the GL7p can no longer be locked until the batteries are replaced Always dispose of used batteries in an environmentally friendly manner e g at an electronic waste r...

Page 33: ...of the GL7p and set them correctly if necessary 4 3 USB Connection To connect to a computer with Windows operating system Windows 7 or higher a Micro B USB port is provided on the side of the GL7p Th...

Page 34: ...ttery Connect the Micro B connector of the USB cable into the USB port on the GL7p o When the GL7p is connected to the computer for the first time the driver is automatically installed and the lock re...

Page 35: ...to be connected b If the lock has already been configured at least once i e the default setting has been deactivated the button must be pressed with the SERVICE data carrier from the Basic Set o The G...

Page 36: ...GL7p Battery powered door mounted electronic locker lock GL7p Commissioning 36 HB_GL7p EN_12 www gantner com...

Page 37: ...tional test to ensure the user and MASTER data carriers and the general lock functionality perform as expected The following data is imported into the GL7p during configuration Site key Sub site numbe...

Page 38: ...with detailed information on each function available in GAT Config Manager To access the manual while the software is open click on the Help menu and select How Do I After installing the software open...

Page 39: ...Figure 5 3 GAT Config Manager Adding a GL7p 5 2 2 View and Edit the GL7p Configuration Settings Once the GL7p has been added to the device list and you have connected the lock to the PC see 4 3 USB Co...

Page 40: ...oad Configuration Settings to the GAT ECO Lock 7xxx F ISO When you are finished configuring the GL7p settings in GAT Config Manager it is important to finalize the configuration by uploading the file...

Page 41: ...tree and select Update Firmware Figure 5 6 GAT Config Manager Updating the GL7p firmware o The Device update wizard opens Figure 5 7 Device update wizard Device selection Select which parts of the GL7...

Page 42: ...ks RFID module Standard RFID reader that reads the data carriers when the button is pressed Click on Next o GAT Config Manager searches the GANTNER server for new firmware versions for the selected ty...

Page 43: ...4 4 0 or later Mobile device must be NFC enabled Mobile device must not be rooted The GL7p must have firmware version 2 4 0 or higher A valid APP KEY data carrier is required for configuring on site...

Page 44: ...ocker where the GL7p is installed can be defined The locker number setting is found here Configuration Operating mode General LockerNumber Enter the locker number for the GL7p into the Locker number f...

Page 45: ...onfiguration Operating mode FreeLocker Select either Duration or Point_of_time from the UseTimeLimit menu for the type of time limit Define the time limit in minutes in the TimeLimit min field 5 4 5 L...

Page 46: ...rier by entering the number of the OPEN MASTER data carrier into 1 of the 10 fields In this case only 9 MASTER data carriers can be used 5 4 8 Wireless Interface For GL7p variants with a wireless inte...

Page 47: ...he time limit Value must be entered in minutes if the most significant bit is not set or in hours if the most significant Bit is set Examples Dec value 1 up to 32767 1 up to 32767 minutes Dec value 32...

Page 48: ...Maced Enciphered List option FileType Type of file Standard Backup List option FileDataOffset Data offset in the DESFire locker file Integer 0 ISO15693 Options for reading ISO 15693 data carriers Gene...

Page 49: ...vious coding Boolean False Master cards MasterCard1 10 Fields to enter number for MASTER data carrier 1 10 Integer License License CertificateCheck When installed is displayed here the certificate che...

Page 50: ...or released while locking Number of cancelled closing operations Integer CNT write on card failed 1 Number of write errors to data carriers first attempt Integer CNT write on card failed 2 Number of w...

Page 51: ...sonal PIN codes remain protected the PIN codes entered are not recorded in the lock bookings and cannot be read To save battery power the GL7p is deactivated in its normal state For this reason the el...

Page 52: ...been unlocked can the user lock another locker in the locker group Locker groups are used to organize the locks within a system into certain functional blocks e g changing room lockers safe deposit b...

Page 53: ...s must be coded accordingly for the duration of use function the corresponding config bits on the data carrier must be set The GL7p must also be configured for the function see section 5 4 4 Duration...

Page 54: ...rsal mode allows the use of data carriers that are also used for other applications No validity date with free locker universal mode It is not possible to use a duration of use time with free locker u...

Page 55: ...approximately 1 second o The information on the data carrier is read a Valid data carrier The LED flashes blue briefly and then green and the action lock unlock is carried out b Invalid data carrier...

Page 56: ...hes red and the GL7p switches off Possible reasons for this include The maximum of 32 data carriers are already authorized in the GL7p The data carrier could not be read correctly e g because the data...

Page 57: ...tion is successful the LED flashes red 3 times and 2 beeps are emitted The GL7p then switches off o All data carriers and PIN codes are now deleted from the GL7p and no longer have the authorization t...

Page 58: ...ed data carriers 3 has a higher index value than in the lock o The new index value and the valid to date of the data carrier are saved in the lock The data carriers previously authorized in the lock l...

Page 59: ...data carriers included in the GAT ECO Basic Set are required to configure and maintain a GL7p equipped locker system The system data carriers are coded to function with specific installations and will...

Page 60: ...a user s data carrier is lost an emergency opening of the corresponding locker can be carried out using an OPEN MASTER data carrier Compared to the MASTER data carrier the OPEN MASTER data carrier can...

Page 61: ...and a beep are emitted to indicate that the antenna calibration has been completed successfully The locker is then unlocked if it was locked before the calibration NOTE The SERVICE data carrier must b...

Page 62: ...he same LED and the integrated beeper LED Beeper Meaning Blue flash Lock ready to read a data carrier Red flash No authorization Error Green flash Data carrier accepted Operation successful Green flas...

Page 63: ...ff dirt and dust using a soft lint free dry cloth For extreme dirt clean the locker components using a slightly moistened cloth Do not allow any moisture to enter the inner parts of the GL7p 7 2 Maint...

Page 64: ...using the dimensions in sections 3 8 Installation of the GL7p and 8 9 Dimensions If the door does not adjust properly mount it in a different position If the door is damaged replace the door with a n...

Page 65: ...type MIFARE supported types MIFARE Classic 1k and 4k MIFARE Ultralight DESFire EV1 and EV2 NFC HCE ISO 15693 HID iCLASS UID 13 56 MHz Note It is recommended to have customer specific data carriers ap...

Page 66: ...face Interface type USB 2 0 Interface connection USB type Micro B Wireless interface NFC 13 56 MHz Wireless 2 4 GHz 8 7 Housing Material Plastic PC halogen free V0 Latch Steel Mounting thread Die cast...

Page 67: ...ator 7 Fixing nut 2 Button a unlocked b locked 8 Spacer sleeve 3 Latch 4 Front part 5 Rear part 6 Mounting thread M19x1 9 Screw for anti rotation protection 10 Battery compartment cover 11 Battery com...

Page 68: ...fo gantner com info gantner nl info aus gantner com London United Kingdom Bochum Germany Los Angeles USA info uk gantner com info de gantner com info us gantner com Ypern Belgium Dubai UAE Ahmedabad I...

Reviews: