GAT Vending 6100 BA
Technical Data
www.gantner.com
HB_GAT-VENDING6100BA--EN_121
43
7
TECHNICAL INFORMATION
7.1 Technical Data
Permitted input voltage U
DC
:
20 to 35 V (MDB)
Max. current consumption:
200 mA
Max. transmission power:
200 mW
Protection:
Surface Mount Fuse AVX F0805B2R00FSTR (2A / 63V, Fast Blow type),
ensures that the GAT Vending 6100 BA operates within the LPS limits.
Frequency of reading field:
13.56 MHz
Reader type:
LEGIC Advant (reads all LEGIC, MIFARE
®
und ISO 15693 data carriers)
Supported data carriers:
- LEGIC Prime
- LEGIC Advant
- MIFARE
®
Classic
- MIFARE DESFire
®
- ISO 15693
Control elements:
- 4 function keys
- RFID reader
Interface elements:
- Graphical black & white display (LCD) with white LED backlight,
resolution 128 x 64 pixels, visible display area = 50 mm x 25 mm
- RFID reader (illuminated)
- Acoustic signal
- LED status bar with LED segments in different colors
Host interface:
Ethernet 10/100 MBit/s
Vending machine interface:
MDB with standard 6-pin connector
Housing material:
- Front part: Plastic PMMA
- Back part: Plastic PC-ABS
Dimensions:
93 mm x 107 mm x 39 mm (3.66´´ x 4.2´´ x 1.54´´)
Permitted ambient temperature:
0 °C to +50 °C (32 °F to 122 °F)
Permitted storage temperature:
-10 °C to +60 °C (14 °F to 140 °F)
Relative humidity:
20 to 80%, non-condensing
Protection type:
IP 54
Protection class:
III
Weight:
Approx. 200 g (0.44 lbs.)
Environment class based on VdS 2110:
II (conditions in indoor areas)
Summary of Contents for GAT Vending 6100 BA
Page 2: ......
Page 46: ...GAT Vending 6100 BA Technical Data 46 HB_GAT VENDING6100BA EN_121 www gantner com ...