5.3.4 List of Configuration Settings
The following table lists all the configuration settings available for the GAT Vending 6100 BA in GAT Config
Manager. A brief description and the format (where applicable) for each setting are shown in the table. Make sure to
enter data in the indicated format for settings such as time definitions, etc.
Options
Description
Format
Default
Communication
Ethernet
Port number
Port used for communication with the device
Integer
8000
MAC address
The MAC address of the device (cannot be changed)
Integer
DHCP enabled
If enabled, will use the IP settings from a DCHP server
Boolean
True
Static IP address
IP address of the device if DHCP is disabled
IPv4 add.
192.168.1.37
Static subnet mask
Subnet mask of the device (if DHCP is disabled)
IPv4 add.
255.255.255.0
Static primary DNS
Primary DNS address of the device (if DHCP disabled)
IPv4 add.
192.168.1.13
Static secondary DNS
Secondary DNS address of the device (if DHCP disabled)
IPv4 add.
192.168.1.11
Static default gateway
Default gateway of the device (if DHCP is disabled)
IPv4 add.
192.168.1.6
NetBIOS name
NetBIOS name of the device
Text
GW + Part No.
+ Serial No.
Dynamic IP address
IP address got from the DHCP Server
IPv4 add.
0.0.0.0
Dynamic subnet mask
Subnet mask got from the DHCP Server
IPv4 add.
0.0.0.0
Dynamic default gateway
Default gateway got from the DHCP Server
IPv4 add.
0.0.0.0
100 MBit Ethernet enabled
Option to enable 100 MBit Ethernet link, 10 MBit if
disabled
Boolean
true
Port Debug
UDP port to assist service technicians with fault diagnosis
Integer
Ident Message Timeout
Timeout setting for the commands "Card Ident Request"
and "Product Vending Request"
Integer
Protocol
Communication mode
Operating mode of the device. Select between
“Online”, “ Emergency” or “Offline”
Menu
Online
Hardware
Display
Contrast
Contrast of the display. Range: 0
– 63. 0: Set to default
Integer
Brightness active mode
Brightness of the display when the device is in
standard operation mode. Range: 0 - 80
Integer
Brightness active mode
Brightness of the display when the device is in energy
saving mode. Range: 0 - 80
Integer
Energy save delay
Idle time in milliseconds before the device switches to
energy saving mode.
Integer
Application
General
Sound signals enabled
Turn on/off sound signals emitted after user activity
Boolean
true
Time format
Format used to display time values on the device.
Select “0 – 24”, “AM / PM” or “Disable”
Menu
0 - 24
Use alternative font
Select to use the alternative font for displaying text
Boolean
False
Font loaded
Description of the currently loaded font data
Device License
License to enable special features of the device
Hex
0000…
Disable Secure UID
Option to disable the Secure UID
Boolean
False
Data handling
Locker 1
Read
Option to read data from the first locker segment of the
data carrier and send to host
Boolean
False
Locker 2
Read
Option to read data from the second locker segment of
the data carrier and send to host
Boolean
False