background image

www.gantner.com

Bestellhinweise

Beschreibung

Art.Nr.

GAT SLR 7300

13,56 MHz Multitechnologie RFID Leser, Slim-Line Aufputz-
gehäuse, RS-485 Schnittstelle

526324

GAT SLR 7307

13,56 MHz Multitechnologie RFID Leser, Slim-Line Aufputz-
gehäuse, RS-485 Schnittstelle, Ausführung IP67 mit 2,9 m 
Anschlusskabel

652728

GAT SLR 7310

13,56 MHz Multitechnologie RFID Leser, Slim-Line Aufputz-
gehäuse, PIN-Code Tastatur, RS-485 Schnittstelle

525424

GAT SLR 7317

13,56 MHz Multitechnologie RFID Leser, Slim-Line Aufputz-
gehäuse, PIN-Code Tastatur, RS-485 Schnittstelle, Ausführung 
IP67 mit 2,9 m Anschlusskabel

652829

Montagesatz GAT SLA-SLR

Montagematerial für die Wandmontage

891182

Order Information 

Description

Part No.

GAT SLR 7300

13.56 MHz multi-technology RFID reader, slim line & wall-
mounted housing, RS-485 interface

526324

GAT SLR 7307

13.56 MHz multi-technology RFID reader, slim line & wall-
mounted housing, RS-485 interface, IP67 version with 2.9 m 
connection cable

652728

GAT SLR 7310

13.56 MHz multi-technology RFID reader, slim line & wall-
mounted housing, RS-485 interface, PIN-code keypad

525424

GAT SLR 7317

13.56 MHz multi-technology RFID reader, slim line & wall-
mounted housing, RS-485 interface, PIN-code keypad, IP67 
version with 2.9 m connection cable

652829

GAT SLA-SLR Mounting Kit

Installation hardware for wall mounting

891182

Typische Anwendung

1  ...... ungesicherter Bereich
2  ...... gesicherter Bereich
3  ...... Zutrittscontroller
4  ...... Netzwerk
5  ...... Versorgungsnetzteil
6  ...... Netzspannung
7  ...... RFID Datenträger
8  ...... elektronisches Schloss
9  ...... Türkontakt

Typical Application

1  ......Unsecured area
2  ......Secured area
3  ......Access controller
4  ......Network
5  ......Power supply
6  ......Mains power supply
7  ......RFID data carrier
8  ......Electronic lock
9  ......Door contact

Die Leser GAT SLR 7300, 7307, 7310 und 7317 dienen 
der Identifikation von Personen unter Ver wendung von 
berührungslosen RFID Ausweisen und werden über die 
strukturierte Gebäudeverkabelung am Zutrittscontroller 
angeschlossen. Dieser Controller, der im gesicherten 
Bereich installiert ist, übernimmt die Auswertung und 
Freigabe der Berechtigungen.

Die Multitechnologieleser lesen und beschreiben die 
am weitest verbreiteten RFID Technologien (LEGIC 
und MIFARE) und können von vielen weiteren 
Ausweistechnologien und RFID Standards die 
Unikatsnummern lesen (z.B. ISO 14443 A und B, ISO 
15693, NFC und HID iClass). 

The GAT SLR 7300, 7307, 7310, and 7317 readers 
are used to identify people via contactless RFID (Radio 
Frequency Identification) data carriers and connect to 
an access controller through structured building cabling. 
The access controller, which is installed in a secured area, 
evaluates and grants access authorizations.

The multi-technology readers read and write the most 
widely used RFID technologies (LEGIC and MIFARE) and 
can read the unique numbers of many other identification 
technologies and RFID standards (e.g., ISO 14443 A and 
B, ISO 15693, NFC, and HID iClass).

GAT SLR 73xx 

Leser für Zutrittskontrolle

DE

EN

DE

EN

DE

EN

FR

FR

weiß

FR

GAT SLR 73xx 

Reader for Access Control

DE

EN

DE

EN

DE

EN

FR

FR

weiß

FR

GAT SLR 730x

GAT SLR 731x

1

GAT SLR 730x

2

3

4

6

5

8

9

7

HID iCLASS

WEB APP

WWW

PC APP

HID iCLASS

WEB APP

WWW

PC APP

HID iCLASS

WEB APP

WWW

PC APP

HID iCLASS

WEB APP

WWW

PC APP

HID iCLASS

WEB APP

WWW

PC APP

HID iCLASS

WEB APP

WWW

PC APP

HID iCLASS

WEB APP

WWW

PC APP

HID iCLASS

WEB APP

WWW

PC APP

Summary of Contents for GAT SLR 7300

Page 1: ...ed area 2 Secured area 3 Access controller 4 Network 5 Power supply 6 Mains power supply 7 RFID data carrier 8 Electronic lock 9 Door contact Die Leser GAT SLR 7300 7307 7310 und 7317 dienen der Ident...

Page 2: ...ngstemperatur 20 bis 50 C Lagertemperatur 20 bis 60 C Schutzart GAT SLR 7300 7310 GAT SLR 7307 7317 IP 64 IP 67 Umweltklasse in Anlehnung an VdS 2110 GAT SLR 7300 7310 GAT SLR 7307 7317 III Bedingunge...

Page 3: ...of device Required measurements for installation 1 LED status display 2 Illuminated scan field 3 Mounting holes 4 Opening 5 Device rear part 6 Flush mounted cable 7 Connection terminals 8 Connection t...

Page 4: ...alle von Servicearbeiten abmontiert werden muss muss zuerst das Ger teoberteil entfernt werden L sen Sie mit einem flachen Werkzeug z B Schraubendreher das Oberteil an der Unterkante des Geh uses inde...

Page 5: ...7 VOut DC 12 24 V wei braun 8 VOut DC 12 24 V braun 4 RJ45 Buchse f r RS 485 Electrical Connections Diagrams CAUTION Electrical shock Always disconnect the power supply before altering electrical conn...

Page 6: ...le Reader und niemals an der Hostschnittstelle und am GAT DC 7200 an den Reader Schnittstellen und niemals an der SUB Schnittstelle erfolgen Empfohlene Kabel Leitungsl ngen Geschirmte und verdrillte D...

Page 7: ...n Sie bei Ihrer Stadt verwaltung oder Ihrem Entsorgungsbetrieb RoHS COMPLIANT RoHS COMPLIANT Only valid for the GAT SLR 7310 and GAT SLR 7317 FCC INFORMATION U S A This equipment has been tested and f...

Reviews: