GAT ECO.Side Lock 7010 (NW) F/ISO
Commissioning
www.gantner.com
HB_GAT-ECOSide-Lock7010-FISO--EN_11
47
5.4.9
MASTER Data Carriers
Up to 10 MASTER data carriers (usually in card format) can be assigned to the GAT ECO.Side Lock 7010 F/ISO to
allow the locker to be opened in special circumstances, e.g., when a user has lost their data carrier. For this
functionality, the MASTER data carriers must be first assigned to the GAT ECO.Side Lock 7010 F/ISO, which is done here:
Configuration > Application > Master cards > Master Card 1 - 10
► Enter the number of each MASTER data carrier into the respective fields.
NOTE!
The MASTER data carrier numbers must be entered in hexadecimal format.
There is also an OPEN MASTER data carrier available (not included in the Basic Set). This special data carrier
can open all lockers (like the MASTER data carriers) but cannot close the lockers. It is possible to program an
OPEN MASTER data carrier by entering the number of the OPEN MASTER data carrier in one of the 10 fields.
In this case only 9 MASTER data carriers can be used.
5.4.10 Configuration Settings Table
The following table lists all the configuration information available for the GAT ECO.Side Lock 7010 F/ISO.
Options
Description
Format
Default
Operating mode
General
Operating mode
Select the operating mode of the lock:
-
“FreeLocker”
-
“PersonalLocker_ProgrammingCard“
-
“PersonalLocker_ExpiryDate”
-
“FreeLocker_UniqueNumber”
-
“FreeLockerUniversal”
List option
Free Locker
Locker number
Enter the locker number here
Integer
30000
Beeper mode
Switch on/off the lock sound signal function
Boolean
True
Alarm mode
Switch on/off the alarm function
Boolean
False
AutoUnlock [min]
Unlock locker at a defined point in time. 0 = inactive
Integer
0
Free Locker
Use TimeLimit
Select the type of time limit for the locker (see "6.3.1. Free
Locker Mode (with or without Duration of Use Function)")
“Duration” or “Point of time”
List option
Duration
TimeLimit (min)
Define the time limit in minutes
Integer
60
TimeLimit
Interrupt
Timeout
[min]
Minimum waiting time from the end of a locker usage period
until the next usage period can begin.
Integer
60
CardValidityDateRequired
When this option is activated, a valid expiration date must be
set on the data carriers so that they can be used (default value
of 1.1.2007 is not valid)
Boolean
False
Personal Locker
Index PersonalLocker
Define the index of the personal locker
Integer
0
PreLock PersonalLocker
Switch on/off the automatic lock function without data
carrier for personal lockers
Boolean
False
PersonalLockerSecureFlag
When this option is activated, a new index or validity date can
only be transferred from a data carrier to the lock when the
locker is open. When this option is deactivated, transferal is
possible even when the locker is locked (see "6.3.5 Personal
Locker Expiry Date Mode")
Boolean
False
LastOpenAtExpiredDate
When this option is activated, a locker can be unlocked one
more time using the data carrier that locked it (see "6.3.5
Personal Locker Expiry Date Mode").
Boolean
True