GAT Access 6100 Terminal Series
Electrical Connections
www.gantner.com
HB_GAT-ACCESS6100--EN_14
35
4
ELECTRICAL CONNECTIONS
This chapter describes how to complete the network, power supply, and peripheral device cabling connections.
Electric Shock
➔
Touching the power cables may result in electrical shock.
- Electrical connections may only be performed by the specified target group.
- Always follow the instructions described in this chapter.
Damage or Malfunction of the GAT Access 6100
-
Read the information in this chapter carefully before connecting the GAT Access 6100.
-
Complete the cabling connections in the sequence and at the terminals/connectors described.
4.1
Target Group
This chapter contains information for personnel responsible for completing the electrical connections. Observe the
legal requirements for electrical installations where the GAT Access 6100 is being installed, e.g., electrical connection
only by suitably trained electricians, material specifications, and tools used. Also observe the environmental operating
conditions of the GAT Access 6100.
4.2
Power Connection
4.2.1
GAT Access 6100 F Enrollment Station
The GAT Access 6100 F Enrollment Station is delivered with its power supply already connected. The power supply
can be plugged directly into a mains power (U
AC
230 V) outlet.
4.2.2
GAT Access 6100 / GAT Access F BIO / GAT TimeAxx6150
These terminals require 12 or 24 VDC (see technical data) supplied via a separate power supply (LPS and SELV -
Limited Power Source and Safety Extra-Low Voltage). GANTNER offers different power supplies, e.g., GAT SP 014/1
(Part No. 557787) or GAT SP 031/1 (Part No. 246933), to suit various applications.
NOTE!
If multiple terminals are sharing a single power supply, always check the maximum power output of the
power supply. For example, one GAT SP 014/1 can supply two GAT Access 6100 terminals.
Summary of Contents for GAT Access 6100 Series
Page 10: ...GAT Access 6100 Terminal Series Table of Contents 10 HB_GAT ACCESS6100 EN_14 www gantner com...
Page 18: ...GAT Access 6100 Terminal Series General Information 18 HB_GAT ACCESS6100 EN_14 www gantner com...
Page 34: ...GAT Access 6100 Terminal Series Installation 34 HB_GAT ACCESS6100 EN_14 www gantner com...
Page 80: ...GAT Access 6100 Terminal Series Operation 80 HB_GAT ACCESS6100 EN_14 www gantner com...
Page 92: ...GAT Access 6100 Terminal Series Troubleshooting FAQ 92 HB_GAT ACCESS6100 EN_14 www gantner com...