Installation, Operation, & Maintenance
G & L Motion Control Inc.
MMC Hardware Manual
27
3.8.6
Diagnostic Error Codes
While the MMC is running, the Diagnostic light (D) on the CPU
module will flash a three digit code signal if there is an error. For
example, if there is a long pause-flash-pause-flash-flash-pause-
flash-flash-flash-long pause, the code is 123. The errors are
described below.
Table 3-3: Diagnostic Light Error Codes
Code
Error
Description
123
Scan too long
A ladder scan loss has occurred because the CPU
takes more than 200 ms to scan the application
program.
124
Excessive overhead
The system overhead update time is excessive.
Consult the factory.
125
Insufficient memory
There is insufficient memory on the CPU to run the
current program.
222
Driver error
No driver support on the CPU for the Option module.
Update your system EPROMs.
22_
Master rack error
An Option Module in the master rack (or the Motion
Control Board in a Standalone MMC Control) do not
match what was declared in the hardware master
declaration table. The number of flashes in the third
digit (_) identifies the slot number that is in error. The
first Option Module is Slot 3.
3_ _
Expansion rack error
The Block I/O modules installed do not match what
was declared in the expansion hardware declaration
table.
The number of flashes in the second and third digits
indicates the block I/O module (01 through 77). The
second digit will flash a 1 - 7, 10 for 0. The third digit
will flash a 1 - 9, 10 for 0.
For example, if the second digit flashes
3
times and
the third digit flashes
10
times, the module
30
is being
reported.
621
Low Battery
The MMC has detected that the on-board battery is
low and needs to be replaced as soon as possible (Not
for Standalone Digital MMC Control).
Summary of Contents for MMC-A2
Page 1: ...Standalone MMC TM Hardware Manual Version 15 0 G L Motion Control Inc...
Page 2: ......
Page 36: ...Installation Operation Maintenance 28 MMC Hardware Manual G L Motion Control Inc...
Page 124: ...Standalone Digital MMC Control 116 MMC Hardware Manual G L Motion Control Inc...
Page 136: ...MMC Ethernet TCP IP Option Module 128 MMC Hardware Manual G L Motion Control Inc...
Page 175: ...CE and EMC Guidelines G L Motion Control Inc MMC Hardware Manual 167...
Page 176: ...CE and EMC Guidelines 168 MMC Hardware Manual G L Motion Control Inc...
Page 177: ...CE and EMC Guidelines G L Motion Control Inc MMC Hardware Manual 169...
Page 178: ...CE and EMC Guidelines 170 MMC Hardware Manual G L Motion Control Inc...
Page 186: ...Appendix A Operation Details 178 MMC Hardware Manual G L Motion Control Inc...