Configuration
64
· G&D VisionXS-F-DP-UHR
Changing the time span of the input lock
When carrying out keyboard or mouse inputs at a console, the KVM extender auto-
matically locks the input devices of the concurrent console. The lock is lifted if no
input is made at the active console within the adjusted timing of the input lock
(default: 1 second).
After the lock has been lifted, both users can operate the computer again.
The time span of the input lock can be adjusted between 1 and 90 seconds.
How to change the timespan of the input lock:
Related topic:
Operating the KVM extender exclusively
IMPORTANT:
The activation of the
Transm. Redundancy
feature, an additional
SFP
transceiver
and the connection to a second console module are prerequisites for this
operation option.
OSD
1. Press
Ctrl+Num
(
default
) to open the OSD.
2. Select the row
System setup
and press
Enter
.
3. Under
Multiuser input lock
enter the desired timespan of the input lock (1 to 90
seconds).
4. Press
F2
to save your settings.