Configuration
G&D VisionXS-F-DP-HR ·
67
English
Activating a console after the permanent switch-off of the
image display
When selecting the
Image display
option
keep off
/
Permanently off
(see page 66 f.) the dis-
play is only switched on again after the time period of the input lock has elapsed
after a user input.
In the standard setting, inputs via both keyboards and mouse cause the display to be
switched on. Alternatively, you can allow
only keyboard
or
only mouse
as triggers to
activate the display of a console.
How to select the valid input device(s) to trigger the activation of a console:
Related topics:
Changing the time span of the input lock
Right for exclusive access to the console
IMPORTANT:
The activation of the
Transm. Redundancy
feature, an additional
SFP
transceiver
and the connection to a second console module are prerequisites for this
operation option.
OSD
1. Press
Ctrl+Num
(
default
) to open the OSD.
2. Select the row
System setup
and press
Enter
.
3. Under
Activation
select one of the following options:
keyb./mouse
(
default
)
keyboard only
mouse only
4. Press
F2
to save your settings.