Status displays
38
· G&D DVIVision
User module (DVIVision-CON)
Range
LED
Status
Meaning
Power
Red.
on
The optional
Power-Set 12/Type 2
power pack
is connected and is supplying 12V.
off
The optional
Power-Set 12/Type 2
power pack
is not (properly) connected
.
Main
on
The main power supply provides the neces-
sary voltage.
off
The switch for the power supply is turned
off or the connection of the device with the
mains supply is not established. Check the
connection of the IEC cable.
Status
Trans.
on
The communication with the computer mod-
ule (DVIVision-CPU) has been established
successfully.
blinking
The communication with the computer mod-
ule (DVIVision-CPU) could not be estab-
lished.
Sys.
on
The system is ready for operation.
slowly blinking
Defective internal communication.
Turn off the device and then turn it back on.
blinking
The setup mode is activated.
fast blinking
only DVIVision-MC3:
The temperature within the device exceeds
75°C
or
the fan is defect.
cyclic flashing
The firmware that is transmitted to the
device through the update assistent is being
transmitted to all system components.
This process can last for several minutes.
Table 5: Status displays at the user module (DVIVision-CON)